Skip to main content

You are viewing a project that is currently in draft state for the Standards Working Group in the Green Software Foundation. This project should not be considered finished or officially supported in any way by the Green Software Foundation or its members.

Software Carbon Intensity for Web Specification (DRAFT SNAPSHOT)

danger

This spec is still in draft state, and awaiting internal review from the Green Software Foundation SCI Web Assembly, and the Software Standards Working Group. Do not treat it like a finished article.

1. Introduction​

This specification extends the Software Carbon Intensity (SCI) methodology to the unique characteristics of web applications. It provides a standardized method for measuring and reporting the carbon emissions associated with software systems that deliver functional value to human users primarily through browser-based interfaces accessed via HTTP/HTTPS protocols.

Web applications consume energy across a distributed system encompassing servers, networks, content delivery systems, third-party services, and end-user devices. Unlike monolithic server-side software, where energy consumption is concentrated in datacenter infrastructure, web applications distribute computation and rendering across infrastructure that no single party fully controls. This specification addresses that distributed reality.

The SCI for Web specification builds upon the core principles established in ISO/IEC 21031:2024 while adding considerations specific to web applications, including their distributed architecture, client-side execution model, dependency on third-party services, and the diversity of end-user devices and network conditions.

This specification aims to:

  • Provide a consistent framework for measuring the carbon footprint of web applications across servers, networks, client devices, and third-party services
  • Enable meaningful comparison between different web application implementations and architectures
  • Guide practitioners in making environmentally responsible decisions in web application design, development, and operation
  • Incentivize carbon efficiency improvements that represent genuine emission reductions rather than displacement or gaming
  • Create market pressure for third-party service providers and hosting suppliers to disclose and reduce their carbon impact

Like the parent SCI specification, SCI for Web is a rate rather than a total: carbon emissions per functional unit. Lower scores indicate better efficiency. Reaching zero is impossible, but continuous improvement is always possible. Reducing an SCI for Web score requires actual elimination of emissions through more efficient code, more efficient infrastructure, or lower-carbon energy sources. Market-based measures such as carbon offsets and renewable energy certificates do not reduce SCI for Web scores.

This specification recognizes that web applications exist across a spectrum of complexity and organizational capability. It provides progressive implementation tiers that enable teams to start measuring with readily available tools and industry defaults, then advance to more sophisticated measurement as capability grows. All tiers are legitimate when methodology is transparently disclosed.

2. Scope​

This specification covers the full spectrum of browser-based web applications, defined by three essential criteria:

  1. Delivery mechanism: Content and functionality delivered over HTTP/HTTPS protocols
  2. Execution environment: Rendering and execution occurring primarily within web browser environments or equivalent web rendering engines
  3. Interaction pattern: Interfaces designed for direct human interaction and consumption rather than exclusively machine-to-machine communication

2.1 Application Types In Scope​

  • Static content websites (blogs, documentation, marketing pages)
  • Dynamic web platforms (content management systems, portals)
  • Single-page applications (SPAs)
  • Progressive web applications (PWAs)
  • Server-side rendered applications
  • E-commerce systems
  • Media streaming services delivered via browser
  • Software-as-a-Service (SaaS) platforms
  • Real-time collaborative tools (document editors, whiteboards, messaging)
  • API-driven applications with browser-based interfaces

2.2 Boundary Cases​

API-driven services require classification based on their primary access pattern:

  • In scope: APIs accessed primarily through browser-based interfaces, such as those with interactive documentation as the primary usage method, or APIs coupled with browser-based management dashboards, where the browser interface represents the primary human interaction mode
  • Out of scope: Pure machine-to-machine APIs serving only programmatic clients; these should use the parent SCI methodology directly

The determining factor is whether human users consume the service's value through browser rendering, not whether HTTP protocols are involved.

2.3 Architectural Patterns In Scope​

  • Client-side rendering (CSR)
  • Server-side rendering (SSR)
  • Static site generation (SSG)
  • Hybrid and incremental rendering (ISR)
  • Serverless and edge computing architectures
  • Micro-frontend architectures

2.4 Specification Structure and Conformance​

Normative vs. Informative Content​

This specification distinguishes between:

Normative sections — Requirements for SCI for Web conformance, using RFC 2119 keywords (SHALL, SHOULD, MAY). Located in the main specification sections (§1–§16).

Informative sections — Implementation guidance, examples, and provisional reference data. Located in appendices and sections explicitly labeled "Informative" or "Non-Normative."

Key distinctions:

AspectNormativeInformative
ConformanceRequired for SCI complianceGuidance only, not required
LanguageSHALL, SHOULD, MAYRecommends, suggests, may consider
ContentMeasurement methods, boundaries, disclosure requirementsService classification tables, provisional coefficients, worked examples
UpdatesVersioned with specificationMay be updated more frequently

Implementation flexibility: Where normative sections require specific actions (e.g., "service-class estimation SHALL use activity metrics appropriate to computational characteristics"), informative appendices provide guidance on implementation approaches (e.g., a service classification table with representative metrics).

Organizations MAY deviate from informative guidance while maintaining conformance with normative requirements, provided deviations are disclosed.

Tiered Conformance (Entry / Standard / Advanced)​

Where normative requirements specify tiered approaches:

  • Entry tier: Baseline requirements sufficient for initial SCI measurement
  • Standard tier: Enhanced methods incorporating application-specific measurement
  • Advanced tier: Refined approaches using detailed instrumentation

All tiers meet conformance requirements. Tier selection is NOT a quality ranking but rather a match between implementation context and measurement feasibility.

Anti-gaming protection: Entry-tier defaults are deliberately conservative (higher embodied emissions, broader allocation) to prevent gaming through strategic tier selection. Organizations with better measurement capabilities are incentivized to advance tiers for accuracy improvement.

3. Normative References​

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document:

  • ISO/IEC 21031:2024 -- Information technology -- Software Carbon Intensity (SCI) specification

4. Terms and Definitions​

For the purposes of this document, the terms and definitions given in ISO/IEC 21031:2024 and the following apply.

ISO and IEC maintain terminological databases for use in standardization at the following addresses:

T.1 Web Application Software system that delivers functional value to human users primarily through browser-based interfaces accessed via HTTP/HTTPS protocols, characterized by browser-mediated human interaction

T.2 Client-Side Energy Energy consumed by end-user devices (desktops, laptops, tablets, smartphones) during browser rendering, JavaScript execution, and interaction with web application interfaces

T.3 Server-Side Energy Energy consumed by origin servers, application servers, database servers, and other backend infrastructure that generates and delivers web application responses

T.4 Network Transfer Energy Energy consumed by network infrastructure in transmitting data between servers and end-user devices, including core internet infrastructure, content delivery networks, and last-mile network access

T.5 Third-Party Service External service integrated into a web application that is not under direct operational control of the web application provider, including but not limited to: analytics services, advertising networks, authentication providers, payment processors, content delivery networks, and API services

T.6 Operational Serving The runtime operation of a web application serving end-user requests, excluding development, testing, and build infrastructure

T.7 Functional Unit (Web-Specific) The unit by which a web application's usage scales, measuring delivered functionality such as user sessions, transactions completed, content items consumed, or tasks performed

T.8 Implementation Tier The level of measurement sophistication adopted by an organization, ranging from entry-level automated measurement to advanced comprehensive instrumentation

T.9 Reference Device A representative end-user device used for standardized client-side energy measurement, selected from defined device categories and performance tiers

T.10 Energy Displacement The practice of shifting computation from measured locations to unmeasured locations to improve metrics without reducing total system energy consumption

The following abbreviations are used throughout this specification in addition to those defined in the parent specification:

  • O_server -- Operational emissions from server-side infrastructure (within datacenter boundary)
  • O_network -- Operational emissions from network transfer (datacenter egress to client device NIC). OPTIONAL component; see §8.3.
  • O_client -- Operational emissions from client-side execution (on end-user devices)
  • M_server -- Embodied emissions from server-side hardware and datacenter infrastructure
  • M_network -- Embodied emissions from network infrastructure (routers, cell towers, cables, exchange points)
  • M_client -- Embodied emissions from end-user devices
  • O_dev -- Operational emissions from development lifecycle (optional; see §6.7)
  • PUE -- Power Usage Effectiveness (datacenter efficiency metric)

Note: O_thirdparty is not a top-level component. Third-party operational emissions are attributed within O_server, O_network, and O_client based on where execution occurs, with mandatory first-party / third-party sub-dimension disclosure per component (see §6.3.1).

5. Web Application Architecture Components​

For the purpose of measuring carbon emissions, a web application system is decomposed into the following components, each contributing to either operational or embodied emissions:

5.1 Server-Side Infrastructure​

Server-side infrastructure encompasses all backend systems that generate, process, and deliver web application responses. This includes:

  • Origin and application servers: Systems executing server-side application logic
  • Database and storage systems: Relational databases, NoSQL stores, object storage, caching layers
  • Edge and CDN infrastructure: Content delivery network nodes, edge computing functions, edge caches
  • Supporting services: Load balancers, reverse proxies, API gateways, service mesh, monitoring systems
  • Serverless execution environments: Function-as-a-Service platforms, edge function runtimes

5.2 Network Transfer​

Network transfer encompasses all data transmission between server infrastructure and end-user devices:

  • Core internet infrastructure: Backbone and transit networks
  • CDN and edge networks: Content delivery and distribution networks
  • Last-mile access: ISP networks, WiFi, mobile/cellular networks

5.3 Client-Side Execution​

Client-side execution encompasses all computation occurring on end-user devices:

  • Browser rendering: Layout, paint, and composite operations
  • JavaScript execution: Parsing, compilation, and runtime execution
  • Asset processing: Image decoding, video playback, font rendering, CSS processing
  • Interaction processing: Event handling, animation, real-time updates
  • Service Workers: Background processing, caching, offline functionality

5.4 Third-Party Services​

Third-party services encompass external services integrated into the web application:

  • Analytics and monitoring: Usage tracking, error reporting, performance monitoring
  • Advertising networks: Ad serving, targeting, tracking
  • Authentication and identity: Login, SSO, identity verification
  • Payment processing: Transaction processing, fraud detection
  • External APIs: Data services, AI/ML services, communication services
  • Client-side scripts: Tag managers, chat widgets, social media embeds

Note: Third-party services are not a separate top-level component in the SCI for Web formula. Their energy consumption is attributed within O_server, O_network, or O_client based on where execution occurs, with a mandatory first-party / third-party sub-dimension per component (see §6.3.1).

5.5 End-User Devices​

End-user devices encompass the hardware on which browsers render and execute web applications:

  • Desktop computers: Workstations, all-in-one systems
  • Laptop computers: Including Chromebooks and similar
  • Smartphones: All mobile phones with web browsers
  • Tablets: Including hybrid devices

6. Persona-Based Software Boundary Definition​

The SCI for Web specification defines measurement responsibilities based on three primary persona groups, each with different spheres of control and agency over the web application's carbon footprint. These personas align with the parent SCI specification's principle that teams should be accountable for elements they can reasonably control or influence.

6.1 Frontend Developer Boundary​

The Frontend Developer boundary encompasses components where frontend developers and design practitioners have direct control over energy consumption:

  • Client-side code efficiency (JavaScript bundle size, execution time)
  • Asset delivery and optimization (images, fonts, videos, CSS)
  • Rendering strategies (progressive enhancement, code splitting, lazy loading)
  • Third-party client-side dependencies (analytics scripts, advertising trackers, external fonts)
  • User interaction patterns (infinite scroll vs. pagination, auto-playing media)
  • Browser caching strategies (service workers, cache headers)

What this boundary measures: O_client (including third-party sub-dimension for client-side scripts the frontend developer chose to include), contribution to O_network (data transferred to client)

What this boundary excludes: Server-side infrastructure decisions, database architecture, hosting provider selection, network infrastructure between datacenter and user, end-user device hardware specifications

6.2 Backend and Infrastructure Engineer Boundary​

The Backend and Infrastructure Engineer boundary encompasses components where backend developers, infrastructure engineers, and DevOps practitioners have direct control:

  • Server-side compute and storage resources
  • Database efficiency and architecture
  • Geographic hosting location and carbon intensity exposure
  • Infrastructure capacity relative to actual traffic (right-sizing)
  • Caching at server and CDN levels
  • API efficiency and server-side code performance

What this boundary measures: O_server (including third-party sub-dimension for server-side API dependencies), M_server, contribution to O_network (server-side network configuration)

What this boundary excludes: End-user device choices, browser vendor implementations, client-side third-party script behavior (though controls whether to include them)

6.3 Product Owner and Technical Manager Boundary​

The Product Owner and Technical Manager boundary encompasses strategic and architectural decisions:

  • Feature prioritization and lifecycle management ("feature gardening")
  • Performance and environmental budget setting
  • Vendor selection and third-party service decisions
  • Team time allocation for optimization
  • Architectural standards and patterns
  • Non-functional requirements including sustainability targets

What this boundary influences: All components (O_server, O_network, O_client, M_server, M_network, M_client) through architectural decisions and prioritization, including third-party service selection whose emissions appear as sub-dimensions within the appropriate operational component (see §6.3.1)

What this boundary excludes: Day-to-day implementation details, supplier internal implementations, end-user behavior and device choices

6.3.1 First-Party vs Third-Party Attribution​

Client-side energy consumption includes all execution on the end-user device, regardless of script origin. This includes first-party application code (the organization's own JavaScript, WASM, rendering logic), third-party scripts executing in the browser (analytics, advertising, chat widgets, embedded media), and hybrid execution (first-party code invoking third-party libraries).

Energy is attributed to the decision maker who introduced the dependency, not the legal entity providing the code:

  • Frontend developer includes analytics widget → O_client (third-party sub-dimension)
  • Backend developer integrates payment API → O_server (third-party sub-dimension)
  • Infrastructure team selects CDN provider → O_network (third-party sub-dimension)
  • User installs browser extension → Not attributed to the web application

Client-side third-party execution is measurable using Long Task API for JavaScript execution time by origin, Resource Timing API for third-party asset loading, JavaScript profiling in browser DevTools, and Real User Monitoring (RUM) tools with script attribution. Where direct attribution is impractical, organizations may estimate using script bundle sizes with disclosed estimation methodology.

O_client MUST be reported with first-party / third-party breakdown:

  • O_client_first: Energy from the organization's own client-side code
  • O_client_third: Energy from third-party scripts executing in the browser
  • Total: O_client = O_client_first + O_client_third

Organizations unable to separate first-party and third-party client execution MUST disclose this limitation and report blended O_client with "attribution: undifferentiated."

The same first-party / third-party sub-dimension applies to O_server and O_network, disclosed even if one side is zero or not separately measurable.

6.4 Consolidated Software Boundary​

While persona boundaries define responsibility and agency, the SCI for Web score is calculated across the consolidated software boundary encompassing all components:

Mandatory inclusions:

  • Server-side infrastructure (origin servers, databases, caching, serverless functions, edge nodes, load balancers, API gateways)
  • Network transfer (all data transmitted between server infrastructure and end-user devices across all network segments)
  • Client-side execution (browser rendering, JavaScript execution, asset processing on end-user devices)
  • End-user devices (embodied emissions allocated proportionally to web application usage)
  • Third-party services (external services providing integral functionality)

Optional inclusions with disclosure:

  • Content Delivery Networks operated or contracted by the web application provider
  • Monitoring and observability infrastructure (if significantly contributing to energy consumption)
  • Redundancy and failover systems (idle failover infrastructure)

Explicit exclusions:

  • Development and build infrastructure (developer workstations, CI/CD pipelines, build processes, automated testing, staging environments) -- to avoid perverse incentives discouraging essential development practices
  • Post-delivery artifacts (email delivery after send, file downloads after transfer, offline processing triggered independently)
  • Native mobile applications (even those using WebViews)
  • Browser extensions, plugins, or assistive technologies

Rationale for development exclusion: Measuring development infrastructure within SCI for Web would create perverse incentives to reduce testing, security scanning, and quality assurance. Development lifecycle energy may be measured separately using the parent SCI methodology.

6.7 Development Lifecycle Operational Emissions (O_dev) — Optional​

O_dev captures operational energy consumed during software development activities: CI/CD pipelines, build processes, automated testing, development environment operation, and version control infrastructure.

O_dev is not required for baseline SCI for Web compliance but is explicitly recognized as a valid supplementary component for organizations seeking comprehensive lifecycle accounting. Including O_dev acknowledges that development is the lifecycle stage where teams have direct measurement control, that pre-deployment energy is attributable to specific software artifacts, and that optimization incentives exist (faster builds, efficient CI/CD, targeted testing).

Organizations including O_dev should define clear boundaries (e.g., from commit to deployment artifact creation), allocate development energy to deployed features proportionally (e.g., by time-to-market or feature complexity), declare measurement methodology and tooling used, and report O_dev separately from the six mandatory components to maintain comparability.

When including O_dev, organizations must define how development energy amortizes over the functional unit. Example approaches include allocating evenly across all instances of R during a deployment period, weighting by feature usage if development was feature-specific, or amortizing over expected feature lifetime.

7. Functional Units​

7.1 General Guidance​

The functional unit (R) for a web application SHALL describe how the application scales and delivers value to users. Following the parent specification, R SHALL be consistent across all components in the software boundary.

For web applications, functional units SHALL measure delivered functionality rather than technical operations. This prevents gaming through quality degradation and ensures SCI scores reflect efficiency of value delivery.

Web applications MAY define multiple functional units representing distinct value-delivery pathways. Complex applications SHOULD define multiple FUs when the application serves distinctly different user journeys or when features have substantially different resource intensities. Each functional unit has its own SCI score. There is no requirement to reduce complex applications to a single headline number.

Comparability across functional units operates at two levels: per-FU comparability (e.g., "purchase completed" SCI is comparable across e-commerce sites) and maturity comparability (organizations tracking more sophisticated FUs demonstrate deeper SCI integration). Comparability weakens as functional units become more application-specific; this is expected and acceptable.

The table below provides suggested examples of commonly used functional units. Given the diversity of web application types and usage models, these examples are indicative and not exhaustive.

Web Application TypeSuggested Functional UnitRationale
Content and media websitesContent item consumed (article read, video watched)Captures delivered value; resistant to page-splitting gaming
E-commerce platformsCompleted transactionAligns with business value delivery; scales with actual usage
SaaS applicationsTask completion (document created, report generated)Measures delivered functionality, not login frequency
Collaboration toolsActive collaboration session or user-hourCaptures sustained engagement and value delivery
API-driven applications with browser UIUser workflow completedMeasures end-to-end value, not individual API calls
Marketing and informational websitesUser session (with engagement threshold)Appropriate for content consumption patterns
Real-time applicationsActive user-minuteCaptures ongoing resource consumption proportionally

7.3 Functional Unit Selection Criteria​

When selecting a functional unit, organizations SHALL consider:

  1. Scaling relationship: The functional unit SHOULD scale proportionally with resource consumption
  2. User value alignment: The functional unit SHOULD represent delivered value, not technical implementation details
  3. Measurability: The functional unit SHALL be objectively measurable from analytics or instrumentation
  4. Stability: The functional unit definition SHOULD remain stable over time to enable comparison
  5. Gaming resistance: The functional unit SHOULD NOT incentivize reducing functionality or quality

7.4 Discouraged Functional Units​

The following functional units SHOULD generally be avoided:

  • Raw page views: Does not account for page complexity or user value delivered
  • API calls: Technical metric easily gamed by consolidating or splitting calls
  • Data transferred: Incentivizes reducing content quality rather than improving efficiency
  • Server requests: Backend technical metric disconnected from user value

Exceptions may exist when these metrics genuinely represent delivered value. If used, justification SHALL be disclosed.

7.5 Reporting Expectations​

Organizations SHALL clearly state:

  • The chosen functional unit and the rationale behind its selection
  • How the functional unit is measured (analytics instrumentation, server logs, etc.)
  • Any engagement thresholds applied (e.g., minimum session duration for "user session")
  • How the functional unit relates to the application's primary value delivery

7.6 Bot Traffic and Non-Human Access​

Bot traffic and non-human access SHALL be handled based on detection capability:

  • Preferred approach: Separate functional units for human and non-human traffic (e.g., R_human for "human page view", R_bot for "bot page view" or "automated API access"), each with its own SCI score
  • Combined reporting: Acceptable when reliable human/non-human separation is not feasible; reported as combined FU with disclosure of detection limitations and estimated bot proportion
  • Exclusion: Permitted only with reliable detection, justification (e.g., malicious bot traffic), and disclosure of exclusion methodology

Organizations MUST disclose: whether bot traffic is included, excluded, or reported separately; what detection method was used; and estimated bot proportion of total traffic. Neither inclusion nor exclusion of bot traffic is inherently correct — comparability comes from transparency.

Engagement thresholds (e.g., minimum 30-second session duration, at least one interaction event) are set by the organization and disclosed. No universal session threshold is mandated, as legitimate session shapes vary too widely across application types. Examples given in this specification are illustrative only and SHOULD NOT be treated as informal defaults — organizations SHALL select thresholds that reflect their actual user-behaviour patterns (a 30-second minimum is inappropriate for marketing or content-discovery sites with legitimately short sessions, for example).

8. Methodology​

8.1 General Formula​

SCI for Web extends the parent specification formula to explicitly decompose web-specific operational and embodied components:

SCI = (O + M) per R

Where for web applications, O is decomposed as:

O = O_server + O_client [+ O_network, optional — see §8.3]

And M is decomposed as:

M = M_server + M_network + M_client

Therefore, the mandatory SCI for Web formula is:

SCI = (O_server + O_client + M_server + M_network + M_client) per R

Organizations MAY additionally include O_network when a defensible methodology is available (see §8.3). When included, the reported SCI score becomes:

SCI (with O_network) = (O_server + O_network + O_client + M_server + M_network + M_client) per R

Where:

  • O_server \= Operational emissions from server-side infrastructure (within datacenter boundary)
  • O_network \= Operational emissions from network transfer (datacenter egress to client device NIC). OPTIONAL — see §8.3 for rationale and methodology requirements.
  • O_client \= Operational emissions from client-side execution on end-user devices (including third-party scripts; see §6.3.1)
  • M_server \= Embodied emissions from server-side hardware
  • M_network \= Embodied emissions from network infrastructure (see §8.8)
  • M_client \= Embodied emissions from end-user device hardware
  • R \= Functional unit measuring delivered value

Why O_network is optional: Operational network emissions are currently difficult to measure defensibly. Widely-used estimation approaches based on bytes-transferred (e.g., SWDM) are acknowledged proxies that can produce misleading results by incentivising apparent efficiency improvements (compression, smaller assets) that do not correspond to reductions in actual network energy use. Rather than mandate a known-weak methodology that could discredit SCI for Web scores, this specification requires reporting without O_network as the baseline, and permits O_network inclusion as a supplementary disclosure when methodology supports it. Embodied network emissions (M_network) remain mandatory because they are structurally present regardless of traffic patterns.

Organizations SHALL disclose whether O_network was included or omitted from their reported SCI for Web score, and if included, the methodology used (see §8.3 and §12.1).

Third-party operational emissions are attributed within O_server and O_client (and within O_network where reported) based on where execution occurs, with mandatory first-party / third-party sub-dimension disclosure (see §6.3.1).

Organizations MAY additionally report O_dev (development lifecycle emissions) as a supplementary component (see §6.7). When reported, O_dev is disclosed separately and does not alter the mandatory formula above.

Each operational component follows the pattern O = E * I from the parent specification, where E is energy consumed in kWh and I is location-based carbon intensity in gCO2eq/kWh.

8.2 Server-Side Operational Emissions (O_server)​

O_server = E_server * I_server

Where:

  • E_server \= Energy consumed by all server-side infrastructure per functional unit (kWh)
  • I_server \= Carbon intensity of electricity consumed by server infrastructure (gCO2eq/kWh)

Energy (E_server) includes energy consumed by:

  • Origin servers and application servers
  • Database servers and caching infrastructure
  • Serverless function execution environments
  • Edge computing nodes (CDN edge servers, edge functions)
  • Supporting infrastructure (load balancers, firewalls, monitoring systems)

Energy consumption SHALL include all energy consumed by hardware reserved or provisioned for the web application, including idle resources, following the parent specification guidance.

If servers are located in datacenters, energy measurements SHALL account for datacenter efficiency by incorporating Power Usage Effectiveness (PUE):

E_server = E_compute * PUE

When measured PUE data is unavailable from the infrastructure provider, organizations SHALL apply a conservative default PUE value at the 75th percentile for the applicable provider category from publicly available datasets:

  • Hyperscale cloud (AWS, Azure, GCP, and equivalent): documented 75th-percentile PUE from provider public sustainability reports or industry surveys
  • Colocation facilities: 75th-percentile PUE from industry benchmarking datasets (e.g., Uptime Institute Global Data Center Survey)
  • On-premise/enterprise datacenter: 75th-percentile PUE from applicable regional benchmarks

Organizations claiming a PUE better than the category 75th-percentile default SHALL document the source of their superior data in the measurement profile. Use of category defaults SHALL be disclosed as a structural limitation in the core measurement profile (see §12.1). Using a PUE value lower than the category 75th-percentile without documented evidence is NOT permitted.

Rationale: Conservative PUE defaults prevent gaming through strategic tier downgrading. An organization with access to genuine Tier 2 data is protected from being disadvantaged because the "documented better-than-default exception" allows use of verified superior data without requiring full Tier 3 instrumentation.

For multi-tenant infrastructure (shared hosting, cloud computing), energy SHALL be attributed based on resource allocation (vCPUs, memory, storage) proportional to total capacity.

Cost-based allocation is explicitly prohibited as a primary allocation method. Cloud or hosting costs change independently of actual resource consumption and carbon footprint (through pricing changes, commitments, spot markets, etc.), making cost a structurally invalid proxy for energy attribution. Cost-based allocation MAY serve only as a disclosed fallback of last resort when resource-based allocation is structurally impossible (e.g., when only cost data is accessible and no resource metrics are available). Organizations using cost-based fallback allocation MUST disclose this limitation explicitly in the core measurement profile and SHOULD document why resource-based alternatives were not accessible.

This prohibition applies to operational energy attribution (allocating shared infrastructure energy to a specific tenant or workload). Cost-based allocation MAY still be used for:

  • M_server embodied emissions allocation when only billing data is available and no resource metrics (vCPU, memory GB) are accessible (disclosed as limitation)
  • Financial reporting of carbon costs (outside the scope of SCI for Web scoring)
  • Internal prioritization of optimization work (not directly affecting reported SCI score)

The distinction: operational energy (O_server) varies with actual utilization and SHALL be attributed by resource share; embodied emissions (M_server) are amortized over hardware lifespan and MAY fall back to cost-based attribution when resource data is unavailable, with explicit disclosure per §12.1.

For geographically distributed server infrastructure:

E_server = SUM(E_region_i) for all regions i

Carbon Intensity (I_server): For geographically distributed systems, carbon intensity SHALL be calculated as an energy-weighted average:

I_server = SUM(E_region_i * I_region_i) / SUM(E_region_i)

Carbon intensity values SHALL use location-based grid carbon intensity, excluding any market-based measures per the parent specification.

8.3 Network Transfer Operational Emissions (O_network)​

Status: O_network is an OPTIONAL component of the SCI for Web score. The mandatory formula (see §8.1) excludes O_network. Organizations MAY additionally report O_network as a supplementary disclosure when a defensible methodology is available.

Why optional: Operational network emissions are currently difficult to measure defensibly. The most widely-used estimation approaches allocate energy based on bytes transferred, which is an acknowledged-weak proxy for actual network energy consumption. Including a mandatory component whose methodology is known to produce misleading results risks discrediting the overall SCI for Web score. This specification therefore separates the reliably-measurable components (O_server, O_client, M_server, M_network, M_client) from the harder-to-measure O_network, and permits but does not require the latter.

If reported, O_network is calculated as:

O_network = E_network * I_network

Where:

  • E_network \= Energy consumed by network infrastructure to transfer data per functional unit (kWh)
  • I_network \= Carbon intensity of electricity consumed by network infrastructure (gCO2eq/kWh)

Methodology hierarchy (when O_network is reported):

Organizations SHALL use the most direct method available and SHALL NOT use bytes-transferred as the sole basis of calculation except as a last-resort fallback with explicit disclosure.

Preferred — Direct Measurement: Where instrumentation is available (e.g., ISP or CDN partner supplying measured energy data for the traffic attributable to the application), direct measurement SHALL be used.

Time-Based Power Modelling — Recommended Non-Bytes Approach: When direct ISP- or CDN-supplied energy measurement is unavailable, organizations SHOULD calculate E_network using time-based power models rather than data-transfer (kWh/GB) proxies. Empirical evidence indicates that network infrastructure energy consumption correlates with active transmission time rather than bytes transferred, as modern network efficiency improvements have partially decoupled energy from throughput at typical web-scale traffic volumes.

The time-based calculation is:

E_network = SUM(duration_segment_i * P_segment_i) (summed across network segments)

Where duration_segment_i is the active transfer duration for segment i (access network, backbone, datacenter egress) and P_segment_i is the average active-state power per connection for that segment drawn from peer-reviewed time-proportional models (e.g., ITU-T L.1310, published networking research).

Transfer duration SHOULD be tracked directly using one or more of the following:

  • Client-side Resource Timing API (performance.getEntriesByType('resource'))
  • Server-side response time logs
  • CDN analytics showing actual delivery times
  • Synthetic monitoring with representative network conditions

When direct duration tracking is unavailable, duration MAY be estimated as bytes_transferred ÷ representative_link_capacity with documented assumptions about representative link capacity. Transfer volume serves as a secondary sense-check: exceptionally large transfers SHOULD correlate with longer durations given network capacity constraints.

Network providers commonly publish "watts per active user" or "watts per active connection" metrics that MAY inform segment-specific power coefficients. Organizations using such coefficients SHALL disclose the source, version, and date of the coefficient values.

The SWD Model v4 is NOT RECOMMENDED as the primary methodology for E_network due to its data-transfer basis. It MAY be used only as a Fallback with full disclosure per the Fallback requirements below.

Acceptable — Hybrid Model: A calculation combining measured or vendor-disclosed network segment data (e.g., last-mile operator energy reports) with modelled remainder. Organizations using this approach SHALL disclose which segments are measured versus modelled, and the rationale for any modelling coefficients.

Fallback — Data-Transfer Estimation: Bytes-transferred proxies (e.g., SWDM, CO2.js coefficients) MAY be used only when no measurement or hybrid approach is available. Organizations using this fallback SHALL disclose: (a) the model and coefficients used, (b) that bytes-transferred is an acknowledged-weak proxy for network energy, (c) why more direct methods were not available, and (d) that the reported O_network value carries high methodological uncertainty.

Data transfer measurement (when used) SHALL include all bytes transferred between server infrastructure and end-user devices, including HTML, CSS, JavaScript, images, videos, fonts, API responses and request bodies, WebSocket and real-time protocols, and HTTP headers and protocol overhead. Data SHALL be measured at the application layer after compression.

Gaming guard: Organizations using bytes-transferred fallback methods SHOULD NOT report reductions in O_network as the primary narrative for efficiency improvements, because bytes-reduction can occur without corresponding network energy reduction (e.g., edge caching shifts energy rather than eliminating it). This aligns with the parent SCI specification's principle that SCI reductions must reflect actual emission reductions, not accounting shifts.

Preventing Double-Counting with CDN and Edge Services:

The boundary between O_server and O_network occurs at datacenter facility egress. CDN and edge services energy is attributed based on measurement regime, not service type:

  1. If measured as facility energy (edge datacenter with PUE, metered infrastructure): include in O_server
  2. If measured as transmission energy (traffic-based, SWDM-style allocation): include in O_network
  3. If bundled by provider without clear separation: organizations MUST disclose which component received the allocation and why

When a provider supplies bundled energy figures, practitioners MUST document which SCI components received portions of the bundled figure, what allocation rationale was used, and what assumptions about measurement regime justified the split.

Illustrative bundled-allocation example (non-normative): A CDN provider publishes a single "CDN total energy for your traffic = 42 kWh/month" figure. An application that uses the CDN for static asset delivery and edge functions may allocate this using a cache-hit-ratio split: if 70% of requests are cache hits served without origin compute, attribute 70% of the 42 kWh to O_network (transmission) and 30% to O_server (edge compute). The operator discloses: the allocation rule, the ratio sources (CDN analytics), and a note that if the CDN publishes component-specific figures in future, the allocation will switch to those.

Connection-Type Weighting: Mobile radio access networks consume roughly an order of magnitude more energy per bit than fiber connections. SWDM default coefficients provide blended averages. Entry Tier organizations may use default SWDM coefficients. Standard and Advanced Tier organizations SHOULD apply connection-type weighting when user traffic distribution is known. Connection-type weighting is encouraged but not mandatory; disclosure of whether weighting was applied is mandatory.

SWDM Double-Counting Rule: When using SWDM, use ONLY the network segment for O_network. Discard SWDM's datacenter and device allocations, replacing them with direct measurement for O_server and O_client. SWDM allocates a single system energy total across three segments; taking network from SWDM and server/client from direct measurement avoids summing overlapping allocations. Organizations using SWDM for O_network MUST disclose the SWDM version and coefficients used, whether connection-type weighting was applied, how edge facility energy was handled, and known limitations.

8.4 Client-Side Operational Emissions (O_client)​

O_client = E_client * I_client

Where:

  • E_client \= Energy consumed by end-user devices for browser rendering and execution per functional unit (kWh)
  • I_client \= Carbon intensity of electricity consumed by end-user devices (gCO2eq/kWh)

Energy (E_client) includes:

  • Browser rendering engine (layout, paint, composite)
  • JavaScript execution (parsing, compilation, runtime)
  • CSS processing and style calculation
  • Asset decoding (images, videos, audio)
  • User interaction processing
  • Service Worker execution

8.4.1 Measurement Observability​

Client-side energy (O_client) sits in a proxy-based measurement domain: browser security models intentionally restrict hardware power telemetry from page-level JavaScript, to prevent side-channel attacks and device fingerprinting. Organizations therefore infer O_client from observable proxy signals — CPU/GPU time, memory allocation, and rendering and network-transfer timing via the browser Performance API — combined with power models, rather than through the direct instrumentation feasible for O_server (§8.2).

This reflects current browser security architecture, not a permanent limitation. Partial or experimental energy signals may emerge in specific environments (OS-level APIs, browser developer tools, specialized hardware), and organizations SHOULD monitor the W3C Web Performance Working Group and browser vendor sustainability initiatives for developments. Requirements for O_client are structured around model transparency, documented assumptions, and explicit uncertainty disclosure (§8.4.7) rather than direct measurement.

8.4.2 Client-Side Energy Estimation Tiers​

Client-side energy estimation SHALL follow one of three tiers, aligned with the Implementation Tiers of §9. Organizations select a tier per device class based on technical capability and available resources; higher tiers provide greater precision but are not required for conformance. An Entry tier implementation using appropriate default models with clear functional-unit boundaries and honest uncertainty disclosure is preferred over a poorly executed Advanced tier with undocumented assumptions.

Entry Tier — Default Reference Models. Organizations SHALL:

  1. Identify the device class(es) relevant to the functional unit, using the categories in §16
  2. Use a published default power model maintained by a recognized organization (Green Software Foundation, W3C Web Performance Working Group, or peer-reviewed research) for each relevant device class
  3. Execute the functional unit on any available device and collect resource-utilization data (CPU time, memory, rendering time, network-transfer timing) via the browser Performance API
  4. Apply the default power model to the collected utilization data
  5. Disclose the device class(es) used, the source of the default power model, the test device (if different from the reference device), and the model's published uncertainty range

Entry tier requires no dedicated test-device fleet or power-measurement equipment — organizations apply models created and validated by specialists rather than creating their own.

Standard Tier — Device-Mix Weighting. Organizations SHALL:

  1. Analyze actual user-device distribution from web analytics data (minimum 90 days)
  2. Identify device classes representing at least 5% of user traffic
  3. For each significant device class, apply either a default reference model (Entry tier) or a custom power model (measurement, manufacturer specification, or published research)
  4. Weight results by actual device-class distribution
  5. Update device-mix weighting at least annually, or when distribution shifts by 10% or more
  6. Disclose device-class definitions, distribution data and source, the power model used per class, and the uncertainty range

Advanced Tier — Validated Custom Models. Organizations SHALL:

  1. Implement Standard tier methodology as baseline
  2. Create custom power models through direct measurement (hardware power monitors, OS-level profiling tools such as Firefox Profiler, Windows Energy Meter Interface, or Linux RAPL/perf, or controlled lab testing)
  3. Validate custom models against at least 3 physical devices per device class, real usage patterns from aggregate RUM data where available, and published research benchmarks
  4. Also report results using the nearest default reference model from the same device class, to preserve comparability
  5. Disclose model-creation methodology, validation results, the comparison against the default reference model, and validation-based uncertainty

Organizations MAY use different tiers for different device classes, provided each assignment is disclosed and justified.

8.4.3 Power Models and Conversion Methodology​

For Entry and Standard tier use of default reference devices, organizations SHALL use published power models from a recognized source: Green Software Foundation reference models, W3C Web Performance Working Group models, peer-reviewed academic power-profiling research (with citation), or manufacturer Thermal Design Power (TDP) specifications with a proportional-utilization formula. Default models SHALL document the model formula and coefficients, component breakdown, validation methodology and uncertainty range, applicable device class, and publication/validity date.

For Advanced tier custom models, organizations SHALL document the evidence basis (hardware power monitors, OS-level profiling tools, or manufacturer specifications), the model formula (e.g., Energy = CPU_time_ms * CPU_coefficient + GPU_time_ms * GPU_coefficient + base_display_power * duration_s), numeric coefficients with units, validation data, and quantified uncertainty (§8.4.7).

Regardless of tier: execute the functional unit on a test device (or devices, for Standard/Advanced device-mix); collect CPU/GPU/memory/network/session-duration utilization via the Performance API (Long Tasks, User Timing, Frame Timing, Resource Timing, Performance Memory where available); apply Energy = Σ(utilization_metric * power_coefficient); weight by device-mix for Standard/Advanced tier; report a point estimate with uncertainty range.

Not acceptable as a power model: an undocumented conversion factor without a cited source; data-transfer volume (GB) as a sole proxy for device energy without demonstrated per-device-class correlation research; a generic "CPU-millisecond-to-kWh" constant applied across heterogeneous device classes; or a conversion factor applied outside its validated device class (e.g., mobile factors applied to desktop).

Acceptable simplified approaches, when documented: average power draw for a device class over session duration (Energy = average_device_power_W * session_duration_s, with averaging assumptions disclosed); manufacturer TDP specifications with utilization fractions; or a published research model applied with explicit citation and a stated device-class applicability. The distinction between acceptable and unacceptable simplified approaches is documentation and source traceability, not model complexity.

8.4.4 Display Energy Attribution​

Display energy is a significant share of device power during web interaction (typically 30–60% for mobile, 20–40% for laptops at default brightness) and SHALL be included in O_client.

Organizations SHALL include it via one of:

  • Integrated in the device power model (any tier): the power model already includes display energy as part of total device power during the session; disclose "display energy included in integrated device power model at default brightness."
  • Separate display component (optional, for higher precision): Display_Energy = display_power_W * session_duration_s, with display technology, size, and brightness assumptions disclosed.

Session duration SHALL be defined and disclosed, based on documented evidence rather than arbitrary assumption: for transaction-based functional units, from initiation through completion (including render and decision time); for page-based functional units, median time-on-page from analytics or published research; for session-based functional units, full session duration.

Entry and Standard tiers are NOT required to model pixel-level content effects (e.g., light/dark mode) or dynamic brightness adjustment — device- or technology-average display power at default settings is acceptable with disclosure. Advanced tier MAY include content-dependent modeling where validated research supports it.

8.4.5 Real User Monitoring (RUM)​

As of this specification's publication, no standard browser API exposes energy consumption (kWh or watts) to page-level JavaScript. Hardware energy counters (e.g., Intel RAPL, ARM PMU) are not exposed to page contexts for side-channel and fingerprinting-resistance reasons, and the Battery Status API has been deprecated in most browsers on privacy grounds. Partial or experimental signals exist in some environments (OS-level APIs, browser developer tools, specialized hardware); organizations SHOULD monitor the W3C Web Performance Working Group and browser security/privacy working groups for developments.

RUM IS feasible and valuable as a source of inputs to power models: resource-utilization timing (navigation, resource, and Long Tasks timing), interaction patterns and session duration, device-class indicators (subject to evolving privacy protections), and page-complexity metrics. The RUM-enhanced pattern (Standard/Advanced tier) is: collect utilization and interaction data from consenting real users; classify sessions by device class; apply device-class power models server-side; aggregate across the device distribution; and use RUM data to validate power-model assumptions (e.g., actual vs. assumed session durations).

Browser developer tools (Firefox Profiler's per-process power on Apple Silicon and Windows 11, Chrome DevTools CPU/GPU profiling, Lighthouse) operate outside the page security sandbox and are appropriate for Entry/Standard tier model creation and validation, but do not constitute production-scale RUM telemetry.

Terminology: "RUM" in this specification means collecting utilization data from real user devices — it does NOT mean direct energy measurement on those devices. Energy is always derived server-side by applying a power model to RUM-collected data.

8.4.6 Active vs. Idle Energy Attribution​

O_client SHALL represent the energy attributable to delivering the functional unit, measured relative to a baseline state appropriate to that functional unit's scope: for transaction-based functional units, an empty tab / minimal static page with no JavaScript execution; for page-view functional units, an empty tab, with page-loaded-but-idle time included per the session-duration definition (§8.4.4); for session-based functional units, browser closed or not in use.

Attributed to the application: CPU/GPU cycles executing application code; memory allocated to application state; network transfers serving application resources; application-triggered rendering; display energy during the active session; and application-initiated background activity (timers, service workers, background polling).

Not attributed to the application (for transaction-based functional units): base browser-process overhead, OS overhead, other tabs or applications, and user activity outside the functional-unit scope.

Where feasible, organizations SHOULD measure differentially: Application_Energy = Energy_During_Functional_Unit - Baseline_Energy. Organizations SHALL disclose the functional-unit scope, the baseline-state definition used, treatment of background tasks/timers, and whether browser overhead is included or excluded.

8.4.7 Uncertainty Quantification and Disclosure​

All O_client values are model-derived estimates and carry irreducible uncertainty from device heterogeneity, user-behavior variation, environmental factors, and model simplification. Organizations SHALL report an uncertainty range alongside each O_client point estimate, determined by: the published uncertainty of a default model (Entry/Standard tier); observed variance from multi-device validation (Advanced tier); sensitivity analysis across plausible parameter ranges; or, absent validation data, a conservative default (suggested ±40% Entry tier, ±30% Standard tier, ±20% Advanced tier with validation).

Example disclosure: "O_client = 0.042 kWh per [functional unit] [±30%] (Standard tier, default reference models, device mix from 90-day analytics, uncertainty from reference-model validation)."

Organizations SHALL NOT claim superiority based on point estimates alone when uncertainty ranges overlap; within-organization longitudinal trends under a consistent methodology are more reliable than cross-organization comparison. Reported precision SHOULD be consistent with the uncertainty range (e.g., "0.042 kWh ±30%", not "0.042368 kWh ±30%").

8.4.8 Explicit Non-Requirements​

To keep this specification implementable, O_client measurement explicitly does NOT require: custom power-model creation (Entry/Standard tiers MAY use published default models); physical power-measurement hardware (default models or literature-based approaches are sufficient); device coverage beyond the functional unit's actual scope; pixel-level display modeling; modeling of user behavioral responses (e.g., brightness adjustment); direct energy measurement on user devices (precluded by browser security models); a single mandatory idle-attribution approach (§8.4.6 — baseline depends on functional unit); or sub-component (CPU/GPU/memory/display) breakdown, though it is encouraged where useful for optimization.

Carbon Intensity (I_client): Organizations SHALL use one of:

  • User-location-based: Weighted average grid carbon intensity based on user geographic distribution
  • Conservative estimate: High percentile (e.g., 75th percentile) of global grid carbon intensity
  • Disclosed assumption: Global average grid carbon intensity with clear disclosure

8.5 Third-Party Service Attribution​

Third-party operational emissions are not a separate top-level component. Instead, they are attributed within O_server, O_network, and O_client based on where execution occurs (see §6.3.1 for the attribution framework).

Normative Requirements​

Third-party services integrated into the application boundary (per §6.3) SHALL be attributed using the following methods in order of preference:

Method A — Vendor Disclosure: Where the third-party vendor provides energy or carbon data per service unit, that disclosed value SHALL be used. Vendor disclosure SHALL include documented methodology, measurement period, and service unit definition. Attribute to the component where execution occurs.

Note: Vendor disclosure remains limited primarily to infrastructure providers (cloud platforms). Organizations SHOULD engage vendors to request standardized energy disclosure, but Method A is not currently achievable for most third-party services.

Method B — Service-Class Estimation: Where vendor disclosure is unavailable, energy SHALL be estimated using activity metrics appropriate to the service's computational characteristics. Estimated energy SHALL be attributed to the component (O_server or O_network) where the service executes, as the relevant third-party sub-dimension (see §6.3.1).

Service classification SHALL be based on the nearest-match computational model. Activity coefficients SHALL be derived from published measurement studies, vendor benchmarks, or documented measurement campaigns with cited sources and explicit uncertainty bounds. Non-normative classification guidance is provided in Appendix B.

Activity coefficients SHALL NOT be universal across all service types. Generic "per API call" coefficients are not permitted.

Method C — Client-Side Measurement: For third-party services executing in the browser, energy SHALL be attributed via client-side measurement per §8.4 methodology, allocated based on script execution time measured via the Performance API and Page Visibility API, and attributed to O_client as the third-party sub-dimension (see §6.3.1).

Client-side measurement is MANDATORY for all third-party scripts loaded by the application, regardless of other attribution methods used for server-side components.

Method D — Exclusion with Mandatory Disclosure: Where a third-party service cannot be measured via Methods A–C and does not meet mandatory inclusion criteria (see Service Inclusion Requirements below), it MAY be excluded from the boundary.

Exclusions SHALL be disclosed per §12 requirements, including service identification, essentiality classification, reason for exclusion, and aggregate energy total for all excluded services combined.

Service Inclusion Requirements​

Third-party services SHALL be classified by essentiality:

Category A (Essential): Services without which the declared functional unit cannot be delivered. These are MANDATORY for measurement or disclosure. Examples tied to functional units:

  • Payment processing for e-commerce transactions
  • Authentication services when user accounts are required
  • Advertising services when the functional unit is ad-funded content delivery

Category B (Enhancement): Services that enhance but are not essential to functional unit delivery (analytics, monitoring, A/B testing). These are subject to materiality thresholds but RECOMMENDED for inclusion where measurable.

Materiality threshold: Services contributing less than 1% of total application energy MAY be excluded per vendor entity, subject to the anti-fragmentation protection below.

Client-side exception: All third-party scripts executing in the browser SHALL be included in O_client measurement regardless of essentiality or materiality thresholds.

Disclosure Requirements​

Organizations SHALL maintain a service inventory disclosing:

  • Service name, vendor, and category
  • Essentiality classification (Category A or B)
  • Measurement method used (A, B, C, or D)
  • Energy contribution (if measured) or reason for exclusion
  • Confirmation of client-side script inclusion

Anti-fragmentation protection: The 1% materiality threshold applies per vendor entity, NOT per API endpoint or service subdivision. Organizations SHALL NOT disaggregate service categories across multiple vendors to circumvent the threshold.

Aggregate energy for all sub-threshold excluded services SHALL be calculated and disclosed. If aggregate exclusions exceed 5% of measured energy, the largest excluded services SHALL be itemized until disclosed exclusions fall below 5%.

Advertising-specific disclosure: For applications using advertising networks:

  • Client-side ad execution (scripts, rendering, asset delivery) SHALL be included via Method C
  • Upstream real-time-bidding (RTB) auction infrastructure (exchanges, DSPs, SSPs, server-to-server bidding) MAY be excluded, per the supplier-internal-implementation exclusion in §6.3
  • Disclosure SHALL state integration model, network providers, and confirm client-side inclusion with explicit acknowledgment that upstream auction energy is excluded

Rationale for upstream exclusion: RTB auctions serve multiple publishers simultaneously with no deterministic per-impression allocation methodology, and auction infrastructure is controlled by third parties outside the application owner's boundary.

8.6 Server-Side Embodied Emissions (M_server)​

Following the parent SCI specification:

M_server = TE_server * TS_server * RS_server

Where:

  • TE_server \= Total embodied emissions of server-side hardware (gCO2eq)
  • TS_server \= Time-share: proportion of hardware lifespan reserved for this web application
  • RS_server \= Resource-share: proportion of hardware resources reserved for this web application

Expanded:

M_server = TE_server * (TiR_server / EL_server) * (RR_server / ToR_server)

For cloud infrastructure where physical hardware details are unavailable, organizations MAY use instance type specifications and embodied emissions databases (e.g., Boavizta, Cloud Carbon Footprint), virtual resource allocation as proxy for resource-share, or cloud provider embodied emissions data if disclosed.

8.7 Client-Side Embodied Emissions (M_client)​

M_client = SUM(TE_device_type * TS_device_type * RS_device_type) for each device type

Where for each device type (desktop, laptop, tablet, smartphone):

  • TE_device_type \= Total embodied emissions for that device type (gCO2eq)
  • TS_device_type \= Time-share: proportion of device lifespan used for this web application
  • RS_device_type \= Resource-share: proportion of device resources used during usage time

Time-share: For a user session of duration D (hours) with device expected lifespan EL_device (hours): TS_device_type = D / EL_device

Measurement Scope​

SCI measurements for client devices are inherently device-specific. Each device category (desktop, laptop, tablet, smartphone) constitutes a separate SCI calculation.

Organizations MAY aggregate device-specific SCI scores into a single weighted metric using actual traffic distribution data (see Optional Device Mix Aggregation below). However, device-specific scores remain the primary normative measurements and SHALL be disclosed individually.

Device Mix: Analytics-Derived Distribution Required​

Normative requirement: Where device mix aggregation is performed, device distribution SHALL be derived from the application's actual analytics data representing real user traffic.

Data requirements:

  • Source: Application analytics showing device category distribution
  • Measurement period: Minimum one calendar year where feasible; if shorter, seasonal skew risk SHALL be disclosed per §14.2
  • Weighting basis: Weighted by functional unit completion (completed transactions, successful actions) rather than raw page views
  • Documentation: SHALL disclose measurement period, analytics source, weighting methodology, and seasonal coverage

Prohibition of generic defaults: Generic device mix defaults (global averages, industry benchmarks) SHALL NOT be used. Applications without analytics data SHALL report device-specific SCI scores separately rather than using assumed distribution.

Rationale: Device mix varies dramatically by application type (enterprise SaaS over 70% desktop; consumer mobile apps over 90% smartphone; e-commerce varies by market). Generic defaults create measurement distortion exceeding acceptable uncertainty bounds.

Optional Device Mix Aggregation​

When analytics-derived distribution is available, organizations MAY calculate an aggregated SCI score:

SCI_aggregated = (SCI_desktop * %_desktop) + (SCI_laptop * %_laptop) + (SCI_tablet * %_tablet) + (SCI_smartphone * %_smartphone)

This aggregated score is supplementary. Device-specific scores remain normative and SHALL be disclosed.

Embodied Emissions Values​

Source hierarchy: Organizations SHALL determine embodied emissions using:

  1. Product-specific LCA data: Manufacturer-published Product Carbon Footprint validated to ISO 14067 or equivalent
  2. Peer-reviewed device-category values: Academic LCA studies with documented methodology
  3. Validated LCA databases: Open databases with disclosed methodology (Boavizta, ADEME Base Empreinte)
  4. Entry-tier conservative defaults: Peer-reviewed reference values (see below)

Entry Tier Conservative Defaults: Organizations without access to product-specific or database values MAY use the following conservative defaults, derived from Lövehagen et al. (2023) empirical LCA measurements (embodied component only, excluding operational use phase):

Device CategoryEmbodied Emissions (kg CO2eq)Expected Lifespan (years)Source
Desktop3504Lövehagen et al. 2023, Table 14
Laptop2004Lövehagen et al. 2023, Table 14
Tablet1003Lövehagen et al. 2023, Table 14
Smartphone503Lövehagen et al. 2023, Table 14

Source citation: Lövehagen, Nina, et al. "Assessing embodied carbon emissions of communication user devices by combining approaches." Renewable and Sustainable Energy Reviews 183 (2023): 113422. DOI: 10.1016/j.rser.2023.113422

Alternative validated source (equally acceptable): Organizations MAY alternatively use ADEME Base Empreinte values (French LCA database, reference 1189, publicly accessible) or Boavizta dataset values (github.com/Boavizta/boavizta-data) with the following adjustments:

If using Boavizta dataset:

  • Use 75th percentile (p75) embodied values to maintain conservative defaults
  • Calculation: gwp_total * (1 - gwp_use_ratio) from source data
  • Values as of main branch 2025-07-07: Desktop 389, Laptop 285, Tablet 93, Smartphone 67 kg CO2eq
  • Acknowledge source limitations per Boavizta documentation (manufacturer-declared data with heterogeneous methodologies)
  • Dataset version SHALL be cited (commit hash or retrieval date)

Note: Boavizta's own documentation states raw manufacturer data "are not transparent and very often have very large margins of error" and recommends against use for precise measurement. Where precision is required, prefer peer-reviewed sources (Lövehagen et al., ADEME).

External monitors (desktop configurations): Desktop configurations with external displays: add 100 kg CO2eq for a representative 24" commercial display (derived from Boavizta display category median).

Excluded peripherals: Keyboards, mice, chargers, docking stations, external storage, printers, webcams, headphones, and similar peripherals SHALL be excluded from M_client unless specifically measured and disclosed.

Rationale: Peripherals lack consistent LCA data, clear attribution to specific applications, and represent immaterial contributions relative to core device embodied emissions.

Mandatory disclosure: Organizations SHALL disclose:

  • Source tier used (product-specific, peer-reviewed, database, or Entry defaults)
  • Specific values in kg CO2eq and assumed lifespans
  • Source citation with publication year or dataset version
  • Device configuration (e.g., "desktop with external monitor" or "laptop integrated display")

Resource-Share Allocation​

Normative requirement (all tiers): RS = 1 (full device allocation) during foreground application execution time, bounded by the Page Visibility API (visibilityState === "visible").

Rationale for full-device baseline:

  1. Internal consistency with O_client operational measurement (§8.4), which uses full-device power without component decomposition
  2. Infeasibility of decomposing embodied share across CPU, GPU, memory, display from the browser sandbox
  3. Prevention of gaming through GPU-intensive workloads (video, WebGL, ML inference) showing low CPU utilization
  4. Temporal disjointness: foreground apps across different applications are disjoint in time, so RS = 1 per app during its window never causes double-counting over device lifetime
  5. Conservative but measurement-complete approach

Optional refinement (native applications only): Organizations with OS-level telemetry access (native apps, managed device fleets) MAY allocate RS based on proportional resource consumption:

RS = (CPU_util * w_cpu) + (GPU_util * w_gpu) + (Memory_util * w_mem) + (Display_time * w_display)

Where component weights reflect per-component embodied cost proportions from device-specific LCA data.

Requirements for proportional RS:

  • Component utilization MUST be measured via OS-level APIs (not estimated)
  • Component weights MUST derive from device-specific LCA showing per-component embodied emissions
  • GPU utilization MUST be included (RS based on CPU alone is prohibited due to gaming potential)
  • Methodology MUST be disclosed

Browser-based applications: For browser-based web applications without OS-level access, RS = 1 is the normative method. Proportional refinement requires native application context.

8.8 Network Infrastructure Embodied Emissions (M_network)​

M_network captures embodied carbon in network infrastructure hardware: routers, switches, cell towers, undersea cables, internet exchange points, and edge points of presence.

Status: M_network is structurally required as a top-level component to ensure completeness and prevent silent exclusion of material emissions. However, allocation of global network embodied carbon to individual web applications presents practical challenges.

Allocation basis (important): Bytes-transferred (data volume) is NOT an acceptable basis for allocating M_network to an individual web application. Network hardware embodied carbon does not meaningfully scale with the amount of data an application sends — it scales with deployment footprint, user count, connection sessions, coverage area, and hardware lifespan. Allocating by data volume creates an incentive structure where apparent reductions in file size correspond to a paper reduction in M_network that does not reflect any real reduction in embodied hardware emissions. This mirrors the rationale for excluding bytes-transferred as the mandatory basis for O_network in §8.3.

Valid allocation bases follow the parent SCI embodied pattern M = TE * TS * RS, where TS is time-share of hardware lifespan and RS is resource-share of hardware capacity. Practical proxies that fit this pattern include active user-sessions, user-hours, concurrent-connection-hours, or vendor-supplied allocation; bytes transferred does not fit this pattern.

Tier-Based Implementation:

  • Entry Tier: May declare M_network as "unpopulated — insufficient allocation methodology" with documented rationale
  • Standard Tier: Should apply industry-default embodied factors (e.g., Boavizta network hardware defaults) using an operator-disclosed non-bytes allocation methodology — for example, active user-sessions, user-hours, or vendor-supplied allocation. Assumptions and the chosen allocation basis MUST be disclosed. Bytes-transferred is not an acceptable allocation basis.
  • Advanced Tier: Should seek vendor-specific embodied data for major network providers (ISP, CDN, mobile operator) where available. Where vendors publish their own allocation methodology, organizations MAY adopt it with disclosure.

Materiality Threshold: Organizations MAY omit M_network population only after documented materiality analysis showing network embodied emissions contribute less than 5% of total embodied emissions (M_server + M_network + M_client). For network-intensive applications (streaming, real-time collaboration, large file transfer), M_network is presumed material unless analysis demonstrates otherwise.

Mandatory Disclosure: Even when M_network is unpopulated, organizations MUST disclose: why allocation was deemed impractical or immaterial, what data sources were evaluated, whether the application profile is network-intensive, and a commitment to revisit as allocation methodologies improve. An unpopulated-M_network declaration SHOULD be revisited at least annually. For network-intensive applications, annual review is REQUIRED.

9. Implementation Tiers​

Organizations SHALL implement one of three measurement tiers for each measured component, based on data availability and measurement sophistication for that component. Tiers apply independently at the component level — a single system MAY achieve different tiers for different components (e.g., Tier 3 for CPU energy, Tier 1 for network energy), reflecting realistic measurement heterogeneity across a deployed system. Organizations SHALL report the tier achieved for each component separately in their measurement profile disclosure (see §12.1). All tiers are legitimate when methodology is transparently disclosed.

9.1 Entry Tier​

Target users: Teams beginning SCI for Web adoption with limited measurement infrastructure.

Requirements:

  • Automated measurement using freely available tools
  • Direct measurement of server-side energy (cloud provider APIs, infrastructure monitoring)
  • Reference device measurement of client-side energy (minimum 1 device per major category)
  • Industry default coefficients for network energy
  • Third-party services estimated using conservative defaults or excluded with disclosure
  • Measurement period minimum 7 consecutive days of representative traffic
  • Full disclosure of methodology, tools, and limitations

Implementation support: Plain-language implementation guides translating Entry Tier requirements into actionable steps for non-specialist personas (product managers, sustainability coordinators, engineering leadership) SHALL accompany this specification as non-normative supporting materials. Reference implementations demonstrating automated measurement profile collection from common platforms (AWS CloudWatch, Azure Monitor, GCP Operations Suite, CDN analytics APIs, browser Resource Timing API) are maintained in Appendix E.

Acceptable data sources:

  • Cloud provider energy/carbon APIs
  • Browser developer tools for client-side profiling
  • Time-based network power models using transfer duration and segment power coefficients (see §8.3); Sustainable Web Design Model as disclosed fallback only when time-based calculation is structurally impossible (see §8.3 Fallback requirements)
  • Default embodied emissions values from this specification
  • Industry default third-party service coefficients

9.2 Standard Tier​

Target users: Teams with established measurement practice seeking improved accuracy.

Requirements:

  • Direct measurement of server-side and client-side energy across representative scenarios
  • Device-mix-weighted client-side measurements (minimum 2 devices per major category)
  • Network energy calculated using validated model (SWDM or equivalent)
  • Third-party services included using vendor data or documented estimation methodology
  • Carbon intensity calculated with daily granularity minimum
  • Measurement period minimum 30 consecutive days or representative business cycle
  • Validation of accuracy against published benchmarks where available
  • Comprehensive disclosure of methodology, data sources, and uncertainty

Acceptable data sources:

  • Infrastructure instrumentation and telemetry
  • Browser profiling across device types
  • Network traffic analysis and modeling
  • Third-party vendor disclosure or API-based estimation
  • Regional grid carbon intensity databases (ElectricityMaps, WattTime, etc.)

9.3 Advanced Tier​

Target users: Organizations with sophisticated measurement capabilities and sustainability commitments.

Requirements:

  • Continuous measurement infrastructure for server-side and network components
  • Real user monitoring (RUM) for client-side energy with statistical sampling
  • Comprehensive third-party service inclusion with vendor engagement
  • Carbon intensity calculated with hourly granularity enabling carbon-aware optimization
  • Geographic and temporal carbon intensity distribution
  • Continuous measurement with regular reporting (monthly/quarterly)
  • Independent validation or audit of methodology
  • Public disclosure of methodology, data sources, and results
  • Embodied emissions using device-specific lifecycle analysis where available

9.4 Quantification Method by Tier​

Organizations SHALL disclose for each component whether measurement or calculation was used:

ComponentEntry TierStandard TierAdvanced Tier
O_serverMeasurement or calculationMeasurement preferredContinuous measurement
O_network (optional)Not reported, or time-based duration model (Tier 1); bytes-transfer fallback only if time-based calculation structurally impossible, with disclosureHybrid or direct measurement where available; data-transfer fallback only if no alternativeDirect measurement or hybrid model; data-transfer fallback strongly discouraged
O_clientMeasurement (reference devices)Measurement (device mix)Measurement (RUM)
M_serverCalculation (defaults or LCA)Calculation (LCA databases)Calculation (specific LCA)
M_networkUnpopulated with disclosureCalculation (industry defaults)Calculation (vendor-specific)
M_clientCalculation (defaults)Calculation (device-specific)Calculation (device-specific LCA)
O_dev (optional)Calculation if includedMeasurement if includedMeasurement if included

Note: Third-party operational emissions are reported as sub-dimensions within O_server, O_network, and O_client (see §6.3.1), not as a separate component row.

9.5 Tier Derivation and Validation​

Tiers are derived, not declared. An organization does not assert which tier a component occupies. Instead, each component's tier is computed automatically from the properties of the measurement actually recorded for it in the structured disclosure (§12.1): the measurement method used, the data source type, and the uncertainty range reported.

The canonical disclosure schema (§12.1) defines, per component type, which combinations of method, primary_data_source type, and uncertainty_range map to which tier. For example: a component measured via vendor_disclosed data with a narrow uncertainty range maps to Standard; one measured via calculation against default industry coefficients maps to Entry; direct instrumentation with validated uncertainty maps to Advanced. The mapping table is part of the normative schema, not left to prose interpretation.

Why derive instead of declare: A declared tier requires every implementer to interpret ambiguous per-tier guidance consistently — in practice this produces disputes over whether a given tool or data source "counts" as Tier 1 vs Tier 2. Deriving the tier mechanically from the measurement properties already being disclosed removes this interpretive step entirely: either the recorded method, source, and uncertainty satisfy a tier's mapping rule, or they do not. There is no separate self-classification to validate, dispute, or audit.

Component independence is preserved. Tier is computed per component, not at the organization level. A system with vendor_disclosed O_server data and calculation-based O_network data is described as Standard for one component and Entry for the other, each derived independently.

Validator responsibility. The reference schema validator (§12.1.1) computes and reports the derived tier per component as part of validation output. Organizations never populate a tier field themselves for measured components; the field is validator-computed from the other required fields and is present in the disclosure purely as a human-readable summary of what the validator derived.

Progression incentives. Organizations are encouraged but not required to progress to measurement approaches that derive a higher tier. Progression is incentivized through:

  1. Transparency signaling: Higher-tier disclosures demonstrate measurement maturity
  2. Uncertainty reduction: Standard and Advanced tiers report narrower uncertainty ranges, improving decision-making confidence
  3. Comparability improvement: Organizations at equivalent tiers for equivalent components produce more directly comparable scores
  4. Ecosystem pressure: As tooling matures and default models improve, Entry tier becomes easier and Standard tier more accessible, creating natural progression pressure without mandates

No mandatory timeline for tier advancement: Organizations SHALL NOT be required to progress to higher tiers by a specified date. Tier choice reflects current capability and organizational priorities. An organization that implements Entry tier and maintains consistent methodology to demonstrate longitudinal improvement is compliant indefinitely.

Recertification is not required: Unlike badge or certification systems, SCI for Web scores do not expire. Organizations SHOULD update scores when methodology improves, infrastructure changes significantly, or annually (whichever comes first), but there is no mandatory recertification cycle.

Context-specific tier requirements: This specification does NOT mandate minimum tiers for specific organizational contexts (large enterprises, public sector, sustainability claims). All organizations are held to the same disclosure requirements; tier choice reflects capability and resource availability, not organizational size or sector.

10. Procedure​

The steps required to calculate and report an SCI for Web score extend the parent specification procedure:

  1. Select Implementation Tier: Choose Entry, Standard, or Advanced tier based on organizational capability and measurement sophistication goals (see Section 9).
  2. Bound: Decide on the software boundary; i.e., the components of the web application system to include. For web applications, this SHALL include at minimum: server-side infrastructure, network transfer, client-side execution, and end-user devices (see Section 6.4).
  3. Scale: Pick the functional unit which best describes how the application scales and delivers value to users. For web applications, this SHOULD measure delivered functionality rather than technical operations (see Section 7).
  4. Define: For each software component listed in the software boundary, decide on the quantification method: direct measurement using instrumentation and telemetry, or calculation using models and industry defaults (see Section 9.4).
  5. Quantify: Calculate a rate for every software component. The SCI for Web value of the whole application is the sum of the component values.
  6. Report: Disclose the SCI for Web score, implementation tier, software boundary, functional unit, calculation methodology, data sources, and limitations following the disclosure requirements (see Section 12).

10.1 Minimum Viable Compliance Pathway​

To maximize accessibility while maintaining credibility, minimum viable compliance is achieved by completing all of the following:

  1. O_server: Tier 1 measurement of at least the CPU energy component, using documented peer-reviewed coefficients (e.g., Boavizta, Cloud Carbon Footprint methodology)
  2. O_network: Tier 1 time-based model — either direct duration tracking or estimated duration (bytes ÷ representative link capacity) multiplied by segment power coefficients (see §8.3). Where time-based calculation is structurally impossible, bytes-transferred proxy is accepted as disclosed fallback flagged "byte-transfer proxy (secondary method)" in the core measurement profile.
  3. M (embodied emissions): Tier 1 database values (Boavizta, Cloud Carbon Footprint, or equivalent peer-reviewed source) with vCPU-hour allocation for M_server, and defaults from §8.7–§8.8 for M_client and M_network
  4. Core measurement profile: Complete disclosure per §12.1 items 1–4 (tier level by component, primary data source per component, measurement period, known structural limitations)
  5. Functional unit definition: Clear specification of R with justification (see §7)

Organizations meeting these five requirements are considered compliant at Entry Tier and SHOULD progress toward Standard and Advanced Tier measurement over time, maintaining historical methodology documentation to preserve valid trend analysis.

11. Implementation Examples​

This section provides examples of how to apply the SCI for Web specification in real-world scenarios.

11.1 E-Commerce Platform Example​

For a typical e-commerce web application, an SCI for Web score is calculated as follows:

Functional Unit: Completed transaction

Boundary: Server-side infrastructure (application servers, database, CDN edge), network transfer, client-side execution, third-party services (payment processor, analytics), end-user devices

Calculation Method:

  1. Measure all mandatory operational and embodied carbon within the software boundary over a defined period (e.g., 30 days):
    • O_server: Energy consumed by application servers, databases, and CDN edge nodes, multiplied by regional carbon intensity. Third-party API calls to payment processor included under O_server (third-party sub-dimension).
    • O_client: Client-side energy per transaction measured on reference devices, multiplied by user-location-weighted carbon intensity. Analytics script execution included under O_client (third-party sub-dimension).
    • M_server, M_network, M_client: Embodied emissions allocated per §8.6–§8.8
  2. Optionally: report O_network separately when a defensible methodology is available (see §8.3). In this example the organisation has chosen not to report O_network because no direct measurement is available and they prefer not to rely on bytes-transferred estimates.
  3. Sum all included components to get total carbon (C)
  4. Count total completed transactions during the period (R)
  5. Calculate: SCI = C / R

Example (mandatory components only):

  • O_server: 2,100 kg CO2eq/month (includes third-party API, 90 kg sub-dimension)
  • O_client: 890 kg CO2eq/month (includes third-party scripts, 120 kg sub-dimension)
  • M_server: 320 kg CO2eq/month
  • M_network: 40 kg CO2eq/month (Boavizta defaults, industry average)
  • M_client: 150 kg CO2eq/month
  • Total C: 3,500 kg CO2eq/month
  • Total completed transactions (R): 500,000/month
  • SCI = 7.00 g CO2eq per completed transaction

The organisation has disclosed that O_network is not included in the reported score and provides rationale in the limitations section.

11.2 Content/Media Website Example​

For a news or media website:

Functional Unit: Content item consumed (article read)

Boundary: Server-side (application servers, CMS, CDN), network transfer, client-side execution, third-party services (analytics, advertising), end-user devices

Example:

  • Total C: 1,250 kg CO2eq/month
  • Total articles read (with engagement threshold of 30+ seconds): 2,000,000/month
  • SCI \= 0.63 g CO2eq per article read

11.3 SaaS Application Example​

For a project management SaaS application:

Functional Unit: Active user session (minimum 5 minutes engagement)

Boundary: Server-side (application servers, database, real-time messaging infrastructure), network transfer, client-side execution, third-party services (authentication, email notification API), end-user devices

Example:

  • Total C: 4,600 kg CO2eq/month
  • Total active user sessions: 150,000/month
  • SCI \= 30.7 g CO2eq per active user session

11.4 Reporting​

For the e-commerce example above, the following should be reported:

  • SCI for Web Score: 7.00 g CO2eq per completed transaction
  • Implementation Tier: Standard
  • Software Boundary: Application servers (AWS eu-west-1), PostgreSQL database, CloudFront CDN, client-side React application, Stripe payment API, Google Analytics
  • O_network Inclusion: Excluded from score. No direct or vendor-disclosed network energy data available; organisation chose not to use bytes-transferred fallback due to acknowledged methodological weakness. Will revisit when CDN partner publishes measured energy data.
  • Functional Unit: Completed transaction (checkout flow resulting in order confirmation)
  • Measurement Period: 2026-01-01 to 2026-01-31 (31 days), average 16,100 transactions/day
  • Component Breakdown: O_server 60% (including 2.6% third-party), O_client 25% (including 3.4% third-party), M_server 9%, M_client 4%, M_network 1%
  • Quantification Methods: O_server measured via AWS Carbon Footprint Tool (Stripe API estimated via Method B, attributed as O_server third-party sub-dimension); O_client measured on 6 reference devices weighted by analytics device mix (Google Analytics script execution estimated via Method C, attributed as O_client third-party sub-dimension); M_network calculated using Boavizta network hardware defaults with active user-session allocation (see §8.8)
  • Carbon Intensity: ElectricityMaps daily average for eu-west-1; global average for client-side
  • Limitations: O_network not reported (see above); third-party analytics client-side energy partially estimated; mobile device measurements limited to 2 models

12. Disclosure Requirements​

12.1 Mandatory Disclosures​

Organizations reporting SCI for Web scores SHALL disclose at minimum the following Core Measurement Profile items (items 1–4), plus the extended mandatory disclosures (items 5–12). The Core Profile ensures baseline interpretability; items 5–12 provide the methodological detail required for independent validation.

Disclosure Format Requirements:

Disclosures SHALL be provided in structured, machine-readable format using one of the following:

  • JSON (recommended for automated processing and validation)
  • YAML (recommended for human readability and documentation)
  • TOML (acceptable alternative)

A canonical JSON Schema defining required fields, permitted values, and validation rules is maintained at [URL to be determined by GSF]. Organizations SHOULD validate their disclosures against this schema before publication.

Human-readable documentation (PDF, HTML, Markdown) MAY accompany structured disclosures but SHALL NOT substitute for them. The structured disclosure is the authoritative source for validation and comparison purposes.

Organizations MAY publish disclosures via:

  • Dedicated disclosure endpoint (e.g., /.well-known/sci-web.json following carbon.txt conventions)
  • Sustainability reporting portal
  • Version-controlled public repository
  • Third-party disclosure registry

Disclosures SHALL include a schema_version field referencing the specific JSON Schema version used for validation.

  1. SCI for Web Score: The calculated value with units (gCO2eq per [functional unit])
  2. Implementation Tier: Tier level reported per component (e.g., "O_server CPU: Tier 2; O_network: Tier 1; M_server: Tier 1"). An overall organization-level tier description is optional supplementary context.
  3. Software Boundary: Complete description of included and excluded components
  4. O_network Inclusion: Whether O_network was included in the reported score. If included, the methodology used (direct measurement, hybrid, or data-transfer fallback) and known limitations. If excluded, this SHALL be stated explicitly.
  5. Functional Unit: Definition of R with justification for selection
  6. Measurement Period: Start date, end date, duration, and traffic characterization
  7. Quantification Methods: For each mandatory component (O_server, O_client, M_server, M_network, M_client) and for O_network if reported:
    • Measurement or calculation approach
    • Tools and instrumentation used
    • Data sources (including third-party data providers)
    • Coefficients and constants used
    • Estimation methodologies where measurement unavailable
  8. First-party / Third-party Breakdown: For each operational component where reported, the first-party / third-party sub-dimension split (see §6.3.1)
  9. Carbon Intensity Data: Sources, temporal granularity, geographic coverage
  10. Limitations and Uncertainties: Components with limited accuracy, excluded third-party services, estimation uncertainties, known gaps, and structural limitations (e.g., serverless architecture preventing hardware telemetry, provider PUE undisclosed, vendor carbon tool used for account-level validation only)
  11. Calculation Date: When the SCI for Web score was calculated
  12. Specification Version: Version of SCI for Web specification used

12.1.1 Structured Disclosure Schema Requirements​

The canonical disclosure schema (JSON Schema format) defines the following minimum required properties for Entry tier compliance:

Document metadata:

  • schema_version: Version identifier of the disclosure schema used
  • spec_version: Version of SCI for Web specification applied
  • calculation_date: ISO 8601 timestamp
  • organization: Legal entity name or identifier
  • application: Application name or identifier

Score and boundary:

  • sci_score: Numeric value with units
  • functional_unit: String describing R with justification field
  • software_boundary: Object with included and excluded arrays
  • measurement_period: Object with start_date, end_date, duration_days

Component-level disclosure (required for each measured component):

  • component: Enum [O_server, O_network, O_client, M_server, M_network, M_client, O_dev]
  • tier: Enum [1-entry, 2-standard, 3-advanced, unpopulated]
  • method: Enum [measurement, calculation, hybrid, vendor_disclosed]
  • primary_data_source: String with tool/database/API name
  • uncertainty_range: Object with lower_bound and upper_bound (percentage)
  • first_party_third_party_split: Object (for operational components only)

O_network inclusion status:

  • o_network_included: Boolean
  • o_network_methodology: Enum [direct_measurement, time_based, hybrid, data_transfer_fallback, excluded] (required if o_network_included: true)

Known limitations:

  • structural_limitations: Array of strings describing measurement constraints
  • excluded_third_party_services: Array of objects with service name and exclusion rationale

Standard and Advanced tier schemas add additional required fields (carbon intensity temporal granularity, device-mix weighting parameters, validation methodology, etc.) but Entry tier compliance requires only the above.

Organizations claiming tier compliance SHALL demonstrate that their structured disclosure validates against the tier-appropriate schema without errors.

  1. Component Breakdown: Individual values for each component
  2. Baseline Comparison: Previous version or alternative implementation comparison
  3. Improvement Actions: Sustainability actions taken between measurements
  4. Third-Party Details: List of services measured, estimated, or excluded
  5. Device Testing Details: Specific device models used for client-side measurement
  6. Geographic Distribution: Server regions and user geographic distribution
  7. Temporal Patterns: Carbon intensity variation during measurement period

12.3 Disclosure Format and Versioning​

Organizations SHOULD provide disclosures in structured, machine-readable format (JSON, YAML, TOML) in addition to human-readable documentation. The structured disclosure is the authoritative source for validation and comparison.

Versioning and archival:

Disclosures SHALL be versioned and archived. Previous versions SHALL remain accessible rather than being overwritten. Each disclosure SHALL include:

  • disclosure_date: When this specific disclosure was published
  • replaces: Reference to previous disclosure version (if applicable)
  • valid_from / valid_until: Time period this disclosure represents (optional but recommended)

Suggested versioning scheme: Organizations MAY use semantic versioning (e.g., 2026-Q1-v1.2), date-based identifiers (e.g., 20260131), or any scheme that provides unambiguous chronological ordering. The schema disclosure_date field is the canonical timestamp.

Retention and auditability:

Historical disclosures provide auditable history of:

  • How scores evolved as methodology matured
  • Impact of infrastructure or application changes
  • Specification version transitions
  • Carbon intensity shifts over time

Organizations making public sustainability claims SHOULD retain historical disclosures for at least:

  • Duration of any active claims referencing the score (minimum)
  • 5 years (recommended for audit trail purposes)

Handling specification updates:

When a new version of SCI for Web specification is published, organizations:

  • MAY continue reporting under the previous specification version (disclose spec_version)
  • SHOULD transition to the new version within a reasonable timeframe (suggested 12-18 months for minor updates, 24 months for major updates)
  • SHALL NOT retroactively recalculate historical scores under new methodology (this breaks trend validity)
  • MAY publish comparative scores under both old and new methodology during transition periods, clearly labeled

Current and historical disclosures SHOULD clearly state which specification version was used, preserving comparability context as the spec evolves.

12.4 Tooling Ecosystem and Discoverability​

Reference implementations: Non-normative reference implementations demonstrating disclosure template generation from common data sources (cloud provider APIs, browser Performance API, RUM platforms) are maintained at [URL to be determined by GSF] and SHALL be updated alongside schema revisions.

Tool neutrality: This specification does not prescribe specific measurement tools for specific tiers. Organizations SHALL disclose tools used but MAY select any tool that satisfies the tier methodology requirements and produces validatable structured disclosures.

Known mature tools (as of specification publication, non-exhaustive):

  • Entry tier server-side measurement: Cloud provider carbon APIs (AWS Customer Carbon Footprint Tool, Google Cloud Carbon Footprint, Azure Emissions Impact Dashboard), Boavizta API, Cloud Carbon Footprint open-source project
  • Entry tier client-side measurement: Firefox Profiler (macOS, Windows 11), co2-runner (demonstration project), Green Metrics Tool (open source, end-to-end measurement for open source projects)
  • Entry tier network measurement: co2.js (JavaScript library with SWD Model and time-based options)
  • Standard tier device-mix measurement: RUM platforms with device classification (though energy calculation remains model-based per §8.4)

Organizations SHOULD monitor the W3C Web Performance Working Group, Green Software Foundation tooling updates, and browser vendor sustainability initiatives for emerging measurement capabilities.

Gap identification: As implementation experience grows, persistent tooling gaps SHALL be documented in the specification maintenance log. Priority gaps for future development include:

  • Production-ready time-based network energy measurement tools
  • Standardized RUM integration patterns for client-side energy attribution
  • Vendor-disclosed network segment energy data (ISP, CDN, cellular operator partnerships)

Discovery and registry:

Organizations publishing SCI for Web scores MAY make them discoverable via:

  1. Endpoint convention (recommended): Publish structured disclosure at /.well-known/sci-web.json or /.well-known/sci-web.yaml following existing .well-known URI conventions. This enables automated discovery and validation without requiring centralized registration.
  2. carbon.txt integration: Organizations already using carbon.txt (Green Web Foundation convention) SHOULD include an sci-web-disclosure field pointing to the structured disclosure location.
  3. Third-party registry submission (optional): Submit disclosure to an independently operated public registry. Registry submission is OPTIONAL and SHALL NOT be required for specification compliance.

Registry governance (if established):

Any public registry of SCI for Web scores SHALL:

  • Operate independently of the specification maintainers to avoid conflicts of interest
  • Accept submissions in standard schema format without modification
  • Retain historical versions with timestamps (not overwrite previous disclosures)
  • Provide clear governance and submission rules
  • Be funded and operated transparently
  • Not gatekeep access to disclosure or comparison functionality behind paywalls

This specification does not establish or endorse a specific registry. Registry establishment is a separate governance question outside the scope of this assembly.

Badges and labels:

This specification does NOT define a standardized badge, label, or certification mark. Visual badges present governance, spoofing, and validation challenges. The structured disclosure itself, retrievable via discovery mechanisms above, is the authoritative source for verification.

Organizations MAY create their own visual representations of SCI for Web scores for marketing or transparency purposes, but SHALL ensure any such representation:

  • Links directly to the authoritative structured disclosure
  • Includes a timestamp or version indicator
  • Does not imply third-party endorsement unless such endorsement exists
  • Clearly states the tier level per component

The absence of a standardized badge is intentional: it shifts focus from certification theater to transparent, machine-verifiable disclosure.

13. Handling of Edge Cases​

13.1 Static Site Generation​

  • O_server includes only energy to serve static files (web server, CDN edge)
  • Build-time generation energy is excluded (development lifecycle)
  • O_client and O_network included as normal

13.2 Single Page Applications (SPAs)​

  • Initial page load and all subsequent API calls included in functional unit
  • Functional unit SHOULD represent complete user workflow, not just initial load
  • Client-side hydration and ongoing JavaScript execution included in O_client

13.3 Progressive Web Applications (PWAs)​

  • Online functionality included normally
  • Offline functionality from cached resources: no O_server or O_network; O_client still measured
  • Service Worker execution included in O_client

13.4 Serverless and Edge Computing​

  • Serverless function execution included in O_server
  • Cold start overhead included (represents actual resource consumption)
  • Edge function execution at CDN nodes included in O_server
  • Allocation methodology for shared infrastructure SHALL be disclosed

For serverless environments where hardware telemetry is architecturally unavailable, organizations SHALL use billing-derived allocation for operational energy estimation:

E_serverless = memory_GB * duration_seconds * E_coefficient

Where E_coefficient is a peer-reviewed energy coefficient (kWh per GB-second) drawn from documented sources (Boavizta, Cloud Carbon Footprint methodology, or equivalent peer-reviewed literature). Billing-derived duration_seconds inherently captures cold start overhead within each invocation window, and no separate cold-start adjustment is required when billing duration is used as the time input. Explicitly reserved capacity (Provisioned Concurrency, reserved instances) SHALL be attributed to the reserving customer rather than distributed across the shared pool.

Organizations using billing-derived allocation SHALL disclose the coefficient source, version, and date. Tier 3 direct hardware telemetry remains architecturally unavailable for serverless paradigms on public cloud; this is a structural limitation of the paradigm and SHALL be documented as such in the core measurement profile — not treated as non-compliance.

13.5 API-First Architectures​

  • Backend API serving energy in O_server
  • Frontend application consuming APIs in O_client
  • Functional unit SHOULD represent end-user value delivery, not individual API calls

14. Measurement Period and Traffic Characterization​

14.1 Minimum Measurement Periods​

  • Entry tier: Minimum 7 consecutive days
  • Standard tier: Minimum 30 consecutive days or one complete business cycle (whichever is longer)
  • Advanced tier: Continuous measurement with monthly or quarterly reporting

14.2 Traffic Characterization​

Organizations SHALL disclose: average and peak traffic levels, traffic distribution (geographic, device types), deviation from typical traffic, and seasonal factors if applicable.

14.3 Normalization​

When comparing SCI scores over time or across implementations, traffic patterns SHALL be normalized to ensure comparable functional unit denominator. Normalization methodology SHALL be disclosed.

14.4 Score Comparability Framework​

SCI for Web scores are directly comparable only within equivalent measurement profiles. Organizations and consumers of SCI data SHALL interpret scores with reference to the following comparability categories:

Primary use case — Longitudinal improvement tracking: An organization tracks its own SCI scores over time using consistent methodology to demonstrate emission reduction trajectories. This is the strongest and most reliable application of the framework. Score reductions under consistent methodology constitute meaningful evidence of efficiency improvement.

Secondary use case — Cohort comparison: Organizations with equivalent measurement profiles (matching tier levels for all compared components, equivalent deployment paradigm, and equivalent functional unit definition) MAY compare scores to understand relative performance within their cohort. Cohort comparisons SHOULD document that measurement profile equivalence has been verified.

Contextualized use case — Cross-tier interpretation: Comparisons between scores from different measurement tiers require explicit disclosure of methodology differences and SHOULD involve expert interpretation of what the tier difference implies for score magnitude. Cross-tier comparisons MUST NOT be used to drive purchasing or policy decisions without appropriate statistical weighting and contextual explanation.

Rationale: Component-level tier independence (see §9) means two scores may differ because one organization measures more accurately, not because it has lower emissions. Score comparisons that do not account for measurement profile equivalence may reflect measurement sophistication rather than actual environmental performance.

15. Carbon Intensity Data Sources​

Carbon Intensity Methodology​

Carbon intensity values used in SCI calculations SHALL be location-based average grid carbon intensity, consistent with ISO/IEC 21031:2024 requirements.

Normative requirement: Reported carbon intensity MUST be labeled as "average carbon intensity" in all disclosures and documentation.

Optional supplementary reporting: Organizations MAY additionally report marginal carbon intensity as a secondary figure for informational purposes, clearly labeled as supplementary and distinct from the normative SCI calculation.

Rationale: Average carbon intensity is required for carbon accounting consistency per GHG Protocol and ISO 14067. Marginal intensity, while useful for operational decision-making, is not suitable for inventory-based carbon accounting and SHALL NOT be used as the primary SCI intensity value.

Market-based measures: Market-based carbon accounting (offsets, RECs, PPAs, EACs) SHALL NOT reduce SCI scores, per ISO/IEC 21031:2024 §6.3 and §18.1 of this specification. SCI reflects actual emissions from energy consumption, not contractual instruments.

Organizations SHALL use location-based grid carbon intensity data. Recommended sources:

Temporal granularity:

  • Entry tier: Annual average acceptable
  • Standard tier: Daily average minimum
  • Advanced tier: Hourly recommended

Fallback hierarchy for carbon intensity data (applied only when the primary source for a given segment is structurally unavailable):

  1. Country-level location-based grid data (minimum requirement): Available from Ember Climate, Electricity Maps API, co2.js, IEA, or national grid operators. This is the baseline; all implementations MUST achieve at minimum country-level attribution per segment.
  2. Regional granularity within countries (encouraged where available): US eGRID subregions, European bidding zones, national transmission operator zones. Provider-disclosed datacenter-specific intensity is acceptable at Standard Tier and above when calculation methodology is documented.
  3. If country-level data is unavailable for a specific segment: regional grid mix (e.g., European grid average when individual country is unidentifiable)
  4. If regional data is unavailable: continental 75th-percentile (conservative, to discourage gaming through strategic geographic ambiguity)
  5. If continental data is unavailable: global average, used ONLY with an explicit flag in the core measurement profile

Rationale for 75th-percentile at steps 4–5: Using a conservative (high) fallback value rather than the mean prevents gaming through deliberate failure to disclose server location or connection geography, while avoiding excessive punishment of operators who genuinely lack the data. Organizations with evidence that their grid mix is cleaner than the fallback default SHOULD document that evidence and use the more accurate value.

16. Reference Devices​

To enable comparable client-side measurements (§8.4), device classes are defined by:

  1. Form factor: mobile phone, tablet, laptop, desktop, television, embedded device
  2. Processor architecture family: x86-64, ARM Cortex-A, ARM Cortex-X, Apple Silicon (M-series), AMD Ryzen generation, Intel Core generation
  3. Performance tier: entry (budget), mainstream, high-performance
  4. Release generation: 2–3 year groupings aligned with chip generation

Default reference device list: This specification references a default list of reference devices maintained by the Green Software Foundation (or a successor organization designated by the SCI for Web maintainers). The list SHALL:

  • Provide at least one reference device per major device class
  • Represent device classes accounting for at least 5% of global web traffic, based on industry analytics
  • Include a documented power model per reference device, with validation methodology and uncertainty range (§8.4.3, §8.4.7)
  • Be reviewed and updated on a 2–3 year cycle aligned with device upgrade cycles
  • Be publicly accessible without licensing restriction

The current default reference device list is published at: [URL to be determined by GSF]

Reference device selection principles: market representativeness (aggregate data from IDC, Gartner, StatCounter, HTTP Archive, or Chrome UX Report); accessibility for validation purposes; architecture diversity (ARM, x86-64, Apple Silicon); power-range coverage within each form factor (e.g., 2–8W mobile, 15–45W laptop, 65–400W desktop); and stability (minimum 2 years on the list, to enable longitudinal comparison).

Example default reference devices (non-normative):

CategoryExample Device
Mobile — Mainstream (2022–2024)Samsung Galaxy S23 (ARM Snapdragon 8 Gen 2)
Mobile — Entry (2022–2024)Motorola Moto G Power (ARM Snapdragon 680)
Laptop — Mainstream (2022–2024)Apple MacBook Air M2
Laptop — High-Performance (2022–2024)Dell XPS 15 9530 (Intel Core i7-13700H)
Desktop — Mainstream (2022–2024)Custom build (AMD Ryzen 7 5700X, mid-range GPU)

Custom devices: Organizations MAY classify and model devices outside the default list when the functional unit targets a context not well-represented by defaults (e.g., embedded systems), organization-specific analytics show significant traffic from an absent device class, or Advanced tier validation justifies it. When used, organizations SHALL document the classification, specify the exact device model, justify why default devices are insufficient, and (Advanced tier) report results against both the custom and nearest default reference model.

Device selection SHALL align with functional-unit scope: organizations are not penalized for testing only the device classes relevant to a well-scoped functional unit (e.g., mobile-only testing for a functional unit with 95%+ mobile traffic).

Organizations SHALL disclose device make, model, OS version, and browser version used for testing.

16.1 Data Source Requirements​

Source Quality Criteria​

Where this specification references external data sources for default values or coefficients, organizations MAY substitute alternative sources meeting the following criteria:

Required characteristics:

  • Publicly accessible or widely available within industry
  • Documented methodology disclosed
  • Peer-reviewed publication OR validated by recognized standards body OR open dataset with documented validation process
  • Updated on a regular cadence (annually or as source data changes)
  • Appropriate geographic or technical scope for the application context

Examples of acceptable source types:

  • Peer-reviewed academic publications (e.g., Lövehagen et al. for device embodied emissions)
  • National/international LCA databases (e.g., ADEME Base Empreinte, Boavizta)
  • Industry benchmarks from recognized bodies (e.g., Uptime Institute for PUE, Ember for grid intensity)
  • Government statistical agencies (e.g., national statistics offices for device usage patterns)

Examples of unacceptable sources:

  • Proprietary vendor data without disclosed methodology
  • Single-company case studies without peer review
  • Undocumented assumptions or estimates
  • Sources without update cadence or version control

Disclosure requirement: Organizations substituting alternative sources SHALL disclose: source name and citation, retrieval date or version, rationale for substitution (why the alternative was chosen over the specification-referenced source), and confirmation that quality criteria are met.

Named Reference Sources (Informative)​

This specification names specific sources (e.g., "StatCounter Global Stats," "Boavizta dataset," "Lövehagen et al. 2023") as reference examples meeting the quality criteria above, not as exclusive mandatory sources.

Named sources represent: commonly available resources accessible to most implementers; validated methodology and regular updates; and sufficient coverage for typical implementation needs.

Organizations MAY use alternative sources meeting quality criteria without seeking approval, provided substitution is disclosed.

16.2 Default Value Update Cadence​

Default values referenced in this specification SHALL be reviewed according to underlying data volatility:

Annual review cycle (high volatility):

  • Carbon intensity regional values (tied to Ember/IEA annual publication cycles)
  • Device usage pattern data (if generic defaults are referenced in informative guidance)
  • Service-class activity coefficients (if material changes in service architecture or new measurement studies)

2–3 year review cycle (moderate volatility):

  • Embodied emissions values (tied to LCA database major updates or publication of new peer-reviewed studies)
  • Device lifespan assumptions (reviewed with embodied values)
  • PUE defaults (tied to Uptime Institute benchmark updates)

Event-triggered review: Defaults MAY be updated outside scheduled cadence when: the underlying source publishes corrections or methodology changes; new peer-reviewed research contradicts existing defaults by more than 20%; market shifts render defaults non-representative; or gaming vectors are identified requiring protective adjustments.

Version control for reproducibility: Organizations SHALL cite: specification version used, dataset version or publication date for sourced defaults, and retrieval date for web-sourced data. This enables reproducible SCI calculations across specification versions.

17. Core Characteristics​

As this specification develops, the following core characteristics SHALL remain true, extending those defined in the parent SCI specification:

  • Sensitivity to web-specific sustainability actions: Actions that reduce emissions in any component (client-side optimization, network transfer reduction, third-party service efficiency, distributed system carbon awareness, caching strategies) SHALL reduce SCI for Web scores.
  • Systems-impact view across distributed architecture: SCI for Web SHALL measure comprehensively across servers, networks, CDNs, third-party services, and client devices to prevent energy displacement.
  • Progressive adoption enabling widespread implementation: SCI for Web SHALL be implementable at different sophistication levels via implementation tiers, enabling teams with varying capabilities to adopt appropriate measurement.
  • Encouragement of granular measurement with pragmatic defaults: SCI for Web encourages the most granular measurement available while providing industry defaults for components where measurement is challenging.
  • Prevention of gaming through comprehensive boundaries and disclosure: SCI for Web SHALL resist gaming (energy displacement, quality degradation, boundary manipulation) through comprehensive boundaries, mandatory disclosure, and functional units measuring delivered value.
  • Alignment with parent SCI principles: All core characteristics of the parent SCI specification are preserved and extended with web-specific guidance.

18. Exclusions​

18.1 Market-Based Measures​

Following the parent SCI specification, the following SHALL NOT reduce SCI for Web scores:

  • Carbon offsets or credits
  • Renewable Energy Credits (RECs)
  • Power Purchase Agreements (PPAs) used to claim carbon-neutral energy
  • Electricity Attribute Certificates (EACs)
  • "Green hosting" certifications based solely on renewable energy purchases

Carbon intensity calculations SHALL use location-based grid carbon intensity excluding market-based adjustments.

18.2 Development and Testing Infrastructure​

Development infrastructure is excluded from SCI for Web scores:

  • Developer workstations
  • CI/CD pipelines
  • Build processes
  • Automated testing systems
  • Staging environments

These MAY be measured separately using parent SCI methodology.

19. Baseline Comparison​

When comparing an improved implementation to a baseline, organizations SHALL:

  1. Maintain identical functional unit
  2. Maintain identical software boundary
  3. Use equivalent traffic profiles
  4. Apply consistent methodology
  5. Document what changed between baseline and comparison
  6. Disclose both scores with methodology

20. Bibliography​

[1] Software Carbon Intensity (SCI) Specification v1.1.0, Green Software Foundation, https://sci.greensoftware.foundation/

[2] Sustainable Web Design Model v4, Sustainable Web Design Community Group, https://sustainablewebdesign.org/calculating-digital-emissions/

[3] Web Sustainability Guidelines (WSG), W3C, https://www.w3.org/TR/web-sustainability-guidelines/

[4] Greenhouse Gas Protocol ICT Sector Guidance, GHG Protocol, https://ghgprotocol.org/

[5] The Net-Zero Standard, Science Based Targets initiative (SBTi), https://sciencebasedtargets.org/net-zero

[6] CO2.js Documentation, Green Web Foundation, https://developers.thegreenwebfoundation.org/co2js/overview/

[7] Boavizta Environmental Footprint Data, Boavizta, https://www.boavizta.org/

[8] Cloud Carbon Footprint Methodology, Cloud Carbon Footprint, https://www.cloudcarbonfootprint.org/docs/methodology


Appendices​

Appendix A: Disclosure Template​

(To be developed: Structured JSON/YAML template for mandatory and recommended disclosures)

Appendix A.1: Non-Normative Implementation Templates​

The following templates are illustrative only and not normative. They are provided to help organizations structure their disclosures and internal analysis. Organizations SHOULD adapt them to their context.

A.1.1 M_network Materiality Analysis Template​

Use when evaluating whether M_network can justifiably be declared unpopulated.

Application profile:
- Application type: [e.g., streaming / e-commerce / SaaS / informational]
- Network-intensive? [yes / no — justification]
- Primary traffic type: [cellular / fixed / mixed, with estimated breakdown]

Materiality estimate (using rough defaults):
- M_server (estimated): [X kg CO2eq / month]
- M_client (estimated): [Y kg CO2eq / month]
- M_network (estimated, industry-default basis): [Z kg CO2eq / month]
- Ratio: M_network / (M_server + M_network + M_client) = [%]

Data sources evaluated:
- [e.g., Boavizta network hardware dataset — accessed / rejected because …]
- [e.g., vendor X sustainability report — available / unavailable]

Decision:
[ ] Populate M_network at Standard Tier using [allocation basis]
[ ] Declare unpopulated — ratio < 5% and application is not network-intensive

Revisit cadence:
[ ] Annual review scheduled for [date]
[ ] Trigger events: [new data source / app profile change / vendor disclosure]

A.1.2 Functional Unit Selection Template (Multi-Purpose Applications)​

Use when an application serves distinctly different user journeys.

Application overview:
- Primary value-delivery pathways:
1. [journey name — e.g., "purchase completed"]
2. [journey name — e.g., "search performed"]
3. [journey name — e.g., "account management session"]

Per-journey FU definition:
For each journey above:
- Name: [FU name]
- Measurement source: [analytics event / server log / synthetic]
- Engagement threshold: [if applicable, with rationale]
- First-party / third-party attribution approach: [method]
- Expected comparability: [cross-org at per-FU level / internal-only]

Reporting plan:
[ ] Report per-FU SCI for each journey
[ ] Do not construct a single aggregate headline SCI
[ ] Declare maturity level: [number of FUs tracked]

Governance:
- Owner(s) of each FU definition: [product / engineering / sustainability]
- Review cadence: [e.g., quarterly]

A.1.3 O_client First-Party / Third-Party Attribution Example​

Illustrative per the §6.3.1 mandatory disclosure.

Component:     O_client
Total: 4.2 g CO2eq per completed transaction
Breakdown:
O_client_first: 3.1 g CO2eq (74% — application JavaScript, rendering, assets)
O_client_third: 1.1 g CO2eq (26% — Google Analytics 0.4g, Intercom 0.5g,
Stripe.js 0.2g)

Measurement approach:
- Long Tasks API for JavaScript execution time by origin (sampled RUM)
- Resource Timing API for asset load energy attribution
- Script bundle size × device-mix-weighted energy coefficient as fallback
where attribution is impractical

Limitations disclosed:
- Google Analytics: client-side execution partially estimated because the
script does not expose fine-grained execution telemetry

A.1.4 CDN Bundled-Vendor-Data Allocation Template​

Use when the CDN provider publishes a single bundled energy figure.

Vendor figure:
- Source: [e.g., CDN provider sustainability portal]
- Period: [e.g., 2026-01-01 to 2026-01-31]
- Bundled energy: [X kWh] for this application's traffic
- Carbon intensity applied: [y gCO2eq/kWh — source]
- Bundled carbon: [X * y] gCO2eq

Allocation rule:
- Rationale: [e.g., cache-hit ratio split]
- Split: [e.g., 70% O_network / 30% O_server]
- Assumptions: [e.g., cache hits are transmission-only;
dynamic edge functions are compute-equivalent]
- Data sources for split: [e.g., CDN analytics dashboard]

Disclosure statement:
"Allocation will transition to vendor-component-specific figures if/when
the provider publishes them."

Appendix B: Service-Class Estimation Guidance (Informative)​

This appendix provides implementation guidance for Method B (Service-Class Estimation) per §8.5. Content here is informative, not normative.

Service Classification Table​

Third-party services SHOULD be classified using the nearest-match computational model:

Service ClassRepresentative Activity MetricsComputational Characteristics
Payment processingCompleted transactions, authorization requests, settlement eventsTransaction validation, fraud detection, ledger updates
AuthenticationLogin events, session creations, token validations, failed attempts, password resetsCryptographic operations, session management, identity verification
Email deliveryMessages sent, delivery attemptsSMTP processing, queue management, spam filtering
Analytics (server-side)Events processed, sessions trackedData ingestion, aggregation, storage
Ad servingImpressions served, ad requestsCreative selection, delivery, auction participation (client-side)
AI/ML inferenceInference requests, tokens processed, model invocationsModel execution, GPU computation
SearchQueries executed, results returnedIndex operations, ranking computation
Media processingAssets processed, processing minutes, transcoding jobsTranscoding, transformation, encoding
Data storage/retrievalOperations executed, GB transferred, API callsI/O operations, data movement
Lightweight servicesAPI calls, function invocationsSimple CRUD, event tracking, static delivery

Fallback for unclassified services: Services not fitting predefined categories SHALL be classified to the nearest computational model with documented justification. Organizations SHALL disclose the classification rationale in the service inventory.

Activity metric breadth: Activity metrics SHOULD capture total service invocation, including failed or incomplete attempts, not only successful outcomes. For example:

  • Payment processing: Include declined transactions, fraud checks, checkout session creation
  • Authentication: Include failed login attempts, password resets, registration events
  • Email delivery: Include delivery attempts, not only confirmed deliveries

Rationale: Computational resources are consumed regardless of outcome success.

Provisional Entry-Tier Coefficients​

Entry-tier implementations MAY use service-class coefficients when published measurement studies exist. Organizations using provisional coefficients SHALL disclose: coefficient source and publication date, measurement methodology from the source study, uncertainty bounds, and aggregate uncertainty introduced by estimation across all third-party services.

Current state: As of 2026, peer-reviewed energy coefficients exist for limited service classes (cloud compute instances, CDN delivery, some email processing). For most third-party SaaS services, Method A (vendor disclosure) or Method D (exclusion with disclosure) remain the realistic options per §8.5.

This appendix will be updated as measurement literature matures.

Appendix C: Worked Calculation Examples​

(To be developed: Step-by-step calculations for each application type with realistic data)

Appendix D: Reference Values and Coefficients​

(To be developed: Compiled reference values for embodied emissions, network energy coefficients, PUE defaults, and other constants)

Appendix E: Tool and Data Source Directory​

(To be developed: Curated list of measurement tools, instrumentation approaches, and data sources for each component)


Document History​

  • Version 0.7.0-draft (2026-10-21): Specification updated based on the outcome of SCI Web II Assembly - Topic 5 -Implementation Tiers, Tooling, and Disclosure  >
  • Version 0.6.0-draft (2026-08-14): Specification updated based on the outcome of SCI Web II Assembly - Topic 4 - Third-Party Service Attribution, Client Device Embodied Emissions, Carbon Intensity Methodology, and Specification Structure  >
  • Version 0.5.0-draft (2026-07-06): Specification updated based on the outcome of SCI Web II Assembly - Topic 3 - Client-Side Measurement >
  • Version 0.4.0-draft (2026-06-29): Specification updated based on the outcome of SCI Web II Assembly - Topic 2 - Server-Side & Network Measurement >
  • Version 0.3.0-draft (2026-04-27): Specification updated based on the outcome of SCI Web II Assembly - Topic 1 - Formula and Functional Units >
  • Version 0.2.0-draft (2026-02-18): First draft specification based on REPORT.md design requirements, structured to align with SCI for AI specification format.
  • Future versions: This specification will evolve through expert assembly, community feedback, implementation experience, and alignment with parent SCI specification updates.